Honeywell Process Solutions Q.Sonic-plus
Honeywell Process Solutions

Q.Sonic-plus six-path ultrasonic gas meter for custody transfer

Ultrasonic flowmeters

Manufacturer
Honeywell Process Solutions
Model
Q.Sonic-plus
Instrument type
Ultrasonic flowmeters
Measuring principle
ultrasonic transit time, 6-path reflective (4 swirl paths with double reflection, 2 single-reflection paths)
Sizes
3 to 24 in (DN 100 to DN 600); up to 56 in on request
Typical uncertainty
0.5 % (zero flow calibration), 0.2 % (high-pressure calibration), 0.1 % (linearisation)
Repeatability
≤ 0.05 %
Pressure ratings
ASME 300 to 600; others on request
Process temperature
−40 to +60 °C standard; −40 to +80 °C extended; −40 to +55 °C MID
Ambient temperature
−40 to +60 °C standard; −40 to +55 °C extended and MID
Inputs/outputs
2 × serial RS-232/485, 1 × Ethernet, 2 × frequency, 2 × digital, 2 × 4–20 mA, 1 × USB
Protocols
Modbus RTU, UNIFORM (incl. Series IV 4-path compatibility mode), MMS, built-in web server
Power supply
24 VDC (18–30 V), 10–20 W
Body material
low-temperature carbon steel; stainless steel engineered to order
Protection
IP66, NEMA 4X
Approvals
MID, ATEX, IECEx, CSA, FM
Standards
OIML R137, ISO 17089 accuracy class 1, AGA 9, IEC 62443-4-1
Request a quote
Review enquiry

The Q.Sonic-plus is a multipath ultrasonic gas flow meter designed for custody transfer of natural gas in large pipelines. Its fields of use are custody transfer, gas exploration, and gas transmission and distribution; natural gas, LNG and hydrogen are listed as media.

The meter uses a six-path reflective configuration. Four swirl paths with double reflection and two single-reflection paths together measure swirl and flow asymmetry in the pipe. This gives profile recognition and extensive diagnostics, resistance to installation effects and a high turndown ratio.

Typical measurement uncertainty is 0.5 % after zero flow calibration, 0.2 % after high-pressure calibration and 0.1 % after linearisation; repeatability is 0.05 % or better. The meter conforms to OIML R137, ISO 17089 accuracy class 1 and AGA 9, and holds MID approval for legal metrology.

Meter sizes range from 3 to 24 in (DN 100 to DN 600), with sizes up to 56 in available on request. Standard pressure ratings are ASME 300 to 600, with others on request. Three temperature versions are available: standard (process and ambient −40 to +60 °C), extended (process −40 to +80 °C, ambient −40 to +55 °C) and MID (process and ambient −40 to +55 °C). The standard body material is low-temperature carbon steel; a stainless steel body is engineered to order.

The electronics provide two serial ports (RS-232/485), one Ethernet port, two frequency outputs, two digital outputs, two 4–20 mA analogue outputs and one USB port. Supported protocols include Modbus RTU, UNIFORM with a Series IV 4-path compatibility mode and MMS, and a built-in web server is available. The meter operates on 24 VDC (18 to 30 V) with a power consumption of 10 to 20 W. The enclosure is rated IP66 and NEMA 4X.

For hazardous areas the meter carries ATEX, IECEx, CSA and FM approvals. Its development process complies with the cybersecurity standards IEC 62443-4-1:2018 and ANSI/ISA-62443-4-1-2018.

The size range is identified by article numbers QS6P080 to QS6P500.

When enquiring, please state the pipe size, pressure rating, gas composition, flow range, temperature version and whether MID custody transfer approval is required.

Part numbers · 10

QS6P080, QS6P100, QS6P150, QS6P200, QS6P250, QS6P300, QS6P350, QS6P400, QS6P450, QS6P500

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments