R5, R6T, R8 and R14 are automatic power factor correction controllers for single-phase networks and for low and medium voltage three-phase networks. They switch capacitor banks in and out so that the installation keeps the target power factor, and they combine compact dimensions with complete functionality for power factor correction systems. Models differ mainly in the number of relay outputs and in their connectivity.
The controllers measure the network parameters with true RMS technology and control the capacitor steps through relay outputs. They work in automatic and manual mode, and operation in cogeneration systems is supported. Auto-acquisition procedures detect the phase relationship, the direction of the current transformer and the power of each bank, which simplifies commissioning. A built-in web server makes the data accessible from a standard browser, and remote monitoring and control are possible via Modbus RTU and Modbus TCP.
Voltage is measured with an accuracy of 0.2 % or 0.5 % ± 0.5 digit and current with 1 % or 0.5 % ± 0.5 digit, depending on the model. The current transformer primary can be set from 5 to 10000 A or 5 to 20000 A with 1 to 5 A secondary, and the voltage transformer primary from 210 to 160000 V or 50 to 200000 V. Capacitor nominal voltages from 50 to 65000 V and step powers from 0 to 999 kvar can be configured. The R14 performs harmonic analysis up to the 60th order, and an internal event log keeps up to one year of history.
Depending on the model, 5, 6, 8, 11, 15, 18 or 29 electromechanical relays are available. Interfaces include Ethernet, RS485, USB 2.0, Bluetooth (BLE), 868 MHz radio and NFC. Analogue input boards for Pt100/Pt1000 and 4–20 mA sensors and expansion boards for additional relay outputs can be fitted.
Information is shown on a graphic 128 × 128 pixel LCD with white LED backlight. The housing is made of PBT thermoplastic polyester with removable terminals and protection up to IP51 at the front and IP20 at the terminals. Versions are available for panel mounting in 96 × 96 mm (92 × 92 mm cut-out) or 144 × 144 mm, and for DIN rail. The operating temperature range is −20 to 70 °C, and the devices are designed to EN 61010-1, EN 61000-6-2/-4 and EN 61326-1.
Typical uses are power factor correction in industrial and commercial facilities, switchboards with several capacitor banks, network monitoring and automation, and cogeneration plants. Please tell us the number of capacitor steps, the network voltage and the interfaces you need.
415988140ENNN, 415988140EBNN, 415988140ESNN, 415988140ENHN, 415988140ECHN, 415988140EAHN, 415988140ENNU, 415988140EBNU, 415988140ESNU, 415988140ENHU, 415988140ECHU, 415988140EAHU, 415988140ENNV, 415988140EBNV, 415988140ESNV, 415988140ENHV, 415988140ECHV, 415988140EAHV, 415988140ENNT, 415988140EBNT, 415988140ESNT, 415988140ENHT, 415988140ECHT, 415988140EAHT, R5, R6T, R8, R14, 415988140NSNN, 415988140NBNN, 415986080NNNN, 415986080NBNN, 415986080NSNN, 415986080QNNN, 415986080QBNN, 415986080QSNN, 415986080ENNN, 415986080EBNN, 415986080ESNN, 415986080NNDN, 415986080NBDN, 415986080NSDN, 415986080QNDN, 415986080QBDN, 415986080QSDN, 415986080ENDN, 415986080EBDN, 415986080ESDN, 315986090NNNN, 315986090NBNN, 315986090NSNN, 315986090QNNN, 315986090QBNN, 315986090QSNN, 315986090ENNN, 315986090EBNN, 315986090ESNN, 315986090NNDN, 315986090NBDN, 315986090NSDN, 315986090QNDN, 315986090QBDN, 315986090QSDN, 315986090ENDN, 315986090EBDN, 315986090ESDN, 415988140NNNN, 415988140QNNN, 415988140QBNN, 415988140QSNN, 415988140QNHN, 415988140NAHN, 415988140NCHN, 415988140QAHN, 415988140QCHN, 415988140QNNU, 415988140NBNU, 415988140NSNU, 415988140QBNU, 415988140QSNU, 415988140QNHU, 415988140NAHU, 415988140NCHU, 415988140QAHU, 415988140QCHU
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.