Sierra Instruments RedyIndustrial
Sierra Instruments

RedyIndustrial thermal mass flow meters and controllers for gases

Thermal mass meters & flow controllers

Manufacturer
Sierra Instruments
Model
RedyIndustrial
Instrument type
Thermal mass meters & flow controllers
Versions
GIM meters; GIC controllers; GIE with external valve
Flow range
0–450 slpm
Accuracy
±1.0 % FS (standard); ±0.3 % FS + ±0.5 % of reading (high)
Turndown
1:50 (standard); 1:100 (high)
Repeatability
±0.2 % FS
Operating pressure
0.2–11 bar a
Response time
approx. 80 ms (meter); approx. 500 ms (controller)
Gases
air, O₂, N₂, He, Ar; multigas option up to 10 gases/mixtures
Supply
24 V DC (18–30 V DC)
Signals
4–20 mA, 0–10 V; Modbus RTU, PROFIBUS DP, PROFINET, EtherCAT
Body / housing
stainless steel 316L / aluminium
Seals
EPDM (FDA); FKM, FFKM optional
Process connection
G¼″ or G½″ BSPP female
Protection
IP67 / NEMA 6
ATEX
II 3G nA IIC T4 Gc; II 3D Ex tc IIIC T100 °C Dc
Request a quote
Review enquiry

The RedyIndustrial series consists of industrial OEM thermal mass flow meters (GIM) and flow controllers (GIC, and GIE with an external valve) for precise measurement and control of gas flow in demanding environments. The devices have a water-resistant IP67/NEMA 6 housing and ATEX approval for Zone 2 and Zone 22.

Measurement is based on high-precision MEMS technology with a CMOS sensor. A constant heat input is applied in the measuring channel, and two temperature sensors (T1 and T2) are positioned upstream and downstream. Gas flow creates a temperature difference that is proportional to the mass flow, and the electronics convert this into a linear indication. The direct mass flow measurement has no moving parts and is not affected by upstream temperature and pressure fluctuations. In the controller versions a valve driver regulates the flow to the set-point.

Flow ranges extend to 0–450 slpm, with low-flow ranges available. Standard accuracy is ±1.0 % of full scale with a turndown of 1:50; the high-accuracy version achieves ±0.3 % of full scale plus ±0.5 % of reading with a turndown of 1:100. Repeatability is ±0.2 % of full scale. The operating pressure range is 0.2–11 bar absolute and the temperature range 0–50 °C. Response time is about 80 ms for meters and about 500 ms for controllers. A multigas option stores up to ten gases or mixtures; listed gases include air, oxygen, nitrogen, helium and argon.

The devices run on 24 V DC (18–30 V DC), drawing up to 100 mA as meters and 250 mA as controllers. Set-points can be given as analogue voltage or current signals or digitally. Analogue 4–20 mA and 0–10 V signals are available, and digital communication options are Modbus RTU over RS-485, PROFIBUS DP, PROFINET and EtherCAT. Electrical connection is by cable gland M16 × 1.5 or M12 plug.

The body is stainless steel 316L and the housing aluminium. Seals are EPDM (FDA) as standard, with FKM and FFKM as options. Process connections are G¼″ or G½″ BSPP female. ATEX marking is II 3G nA IIC T4 Gc and II 3D Ex tc IIIC T100 °C Dc. A factory calibration certificate is included, and DAkkS calibration is available on request. The gas must be clean and dry; a 50 µm inlet filter is recommended, and horizontal mounting is preferred.

Listed applications include biopharmaceutical bioreactors, food and beverage manufacturing, fuel cell development, photonics, washdown environments, semiconductor manufacturing, chemical processing and laboratories, including toxic, flammable gases and oxygen service. Please send the gas, flow range, pressure and required interface with your enquiry.

Part numbers · 10

GIM-A, GIM-B, GIM-C, GIM-D, GIC-A, GIC-B, GIC-C, GIC-D, GIE, PDM-U

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.