SGC 421 is a single genset controller for automatic mains failure (AMF) applications. It protects and controls the generator set, the genset breaker and the mains breaker, and adds two functions that are useful on remote sites: electronic governing for engines with mechanical fuel systems and advanced management of the site battery charge.
For speed control, the controller drives a rotary actuator through its stepper motor output, rated up to 800 mA, so an engine with a mechanical fuel system can be operated with electronic governing. The controller also monitors the site battery voltage, which helps to reduce fuel consumption by running the genset only as needed, and the shelter temperature. A deep sleep function extends battery life when the unit is idle. Supported operating modes include island (off-grid) operation, remote start and stop and cyclic exercise.
Measuring inputs cover generator and mains voltages of 32 to 300 V AC phase-neutral and 32 to 520 V AC phase-phase, current via 5 A inputs and frequency from 5 to 75 Hz. A separate 5 A input serves earth leakage or fan current. Engine signals are acquired through 9 digital inputs, 5 resistive analogue inputs, an analogue input for 0–5 V DC or 4–20 mA, a magnetic pick-up input for 10 to 10,000 Hz at 200 mV to 45 V AC, and a D+ charger alternator input. Seven configurable digital outputs are provided, two rated 5 A and five rated 1 A.
Communication interfaces are USB 2.0 (type B), RS-485 with Modbus and CAN bus. A full graphics LCD shows operating data, with menu languages including English, Chinese and Spanish. The controller runs on a 12 or 24 V DC auxiliary supply with an operating range of 8 to 32 V DC; maximum consumption is about 200 mA, standby consumption 180 mA at 12 V and 140 mA at 24 V.
The unit is panel mounted, measures 173 × 233 × 38.5 mm and operates from −20 to 65 °C, with IP65 and IP20 ratings listed. It is approved to UL 6200 and ULC 6200 and tested to IEC 60068-2, EN 61010-1, EN 61000-6-2 and EN 61000-6-4. A rotary actuator for governing and an optional PLC extension are available.
Please describe the genset and engine fuel system, the operating mode and whether the rotary actuator should be included.
SGC 421
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.