Brooks Instrument SLAMF
Brooks Instrument

SLAMF elastomer-sealed thermal mass flow controllers and meters, IP66

Thermal mass meters & flow controllers

Manufacturer
Brooks Instrument
Model
SLAMF
Instrument type
Thermal mass meters & flow controllers
Measuring principle
thermal mass flow
Medium
gas
Flow range
0.003 to 2500 slpm (meters to 9000 slpm)
Accuracy
±0.6 % of setpoint (20–100 % FS); ±0.12 % FS (< 20 % FS)
Repeatability
0.20 % of setpoint
Turndown
100:1 (1–50 slpm); 50:1 (50–2500 slpm)
Maximum pressure
1500 psi
Operating temperature
−14 to 65 °C
Seals
elastomer
Enclosure
IP66
Hazardous area
Class 1 Div 2, Zone 2
Communication
analogue 0–5 V, 0–10 V, 0–20 mA, 4–20 mA; RS-485, DeviceNet, PROFIBUS, EtherNet/IP, PROFINET, EtherCAT
Models
SLAMF50, SLAMF51, SLAMF53, SLAMF60, SLAMF61, SLAMF63, SLAMF64
Compliance
ISO/IEC 17025 calibration, EU REACH
Request a quote
Review enquiry

The SLAMF series comprises thermal mass flow controllers and meters with elastomer seals, built in an IP66 rated hardened enclosure for precise gas flow measurement and control in harsh industrial environments. Controllers measure the gas flow and regulate it to a setpoint; meters measure only. Seven models are listed: SLAMF50, SLAMF51, SLAMF53, SLAMF60, SLAMF61, SLAMF63 and SLAMF64.

The devices use thermal sensing technology to measure gas mass flow directly. They are programmable for multiple gases and ranges, so one instrument can be set up for different gases and full-scale values. Advanced self-test routines allow diagnostics without removing the device from service, and a user-accessible service port simplifies installation and troubleshooting. Service software and a LabVIEW DLL are available.

The flow range extends from 0.003 slpm to 2500 slpm for controllers and up to 9000 slpm for meters. Accuracy is up to ±0.6 % of setpoint between 20 and 100 % of full scale and ±0.12 % of full scale below 20 %. Repeatability is 0.20 % of setpoint. The turndown ratio is 100:1 for ranges from 1 to 50 slpm and 50:1 for ranges from 50 to 2500 slpm. The instruments are rated for pressures up to 1500 psi and operating temperatures from −14 °C to 65 °C. Calibration is performed under ISO/IEC 17025.

For integration into control systems, analogue I/O with 0–5 V, 0–10 V, 0–20 mA or 4–20 mA is available, as well as digital communication over RS-485, DeviceNet, PROFIBUS, EtherNet/IP, PROFINET and EtherCAT, with various analogue and digital I/O configurations.

The enclosure is IP66 rated, and the series carries Class 1 Div 2 and Zone 2 approval for hazardous areas. The products comply with EU REACH. Biotech options packages are offered.

Listed applications are life sciences, bioprocessing, chemical and petrochemical pilot plants and blanketing in food processing.

To select the right model, please send the gas, flow range, inlet and outlet pressure, whether a controller or a meter is needed, and the required communication interface.

Part numbers · 7

SLAMF50, SLAMF51, SLAMF53, SLAMF60, SLAMF61, SLAMF63, SLAMF64

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU