EDT 101
Temperature

Thermocouples
The T.4.-0 is a compact and robust stick-in temperature sensor made of stainless steel with a type K or type J thermocouple. It is designed for industrial and maritime environments and is fixed in place with a compression fitting. The cable leaves the sensor laterally at 90°.
A thermocouple consists of two different metals joined at the measuring point; the junction produces a voltage that depends on temperature. The T.4.-0 uses type K (NiCr-Ni) or type J (Fe-CuNi) thermocouples and measures temperatures up to 800 °C. The stated tolerance is class B according to DIN EN 60571; other accuracy classes are available on request.
The sensor tube is made of stainless steel. Standard immersion depths are 100 mm, 150 mm, 200 mm and 250 mm, and other lengths are available on request. The sensor is supplied with a fixed connection cable, and different cable lengths can be ordered. As an option, the sensor can contain two thermocouples, which provides a second measuring circuit from the same measuring point.
The sensor holds DNV and LR certificates, which supports its use in shipbuilding.
In summary, a sensor is defined by five ordering parameters: thermocouple type (K or J), number of thermocouples (one or two), immersion depth (100, 150, 200 or 250 mm or a special length), cable length and accuracy class (class B as standard or another class on request). All versions share the stainless steel sensor tube, the compression fitting and the 90° lateral cable outlet.
Listed fields of use are the shipbuilding industry, megayachts, transport technology, defence, machinery and equipment, and meteorology.
For a quotation, please state the thermocouple type, single or double element, immersion depth, cable length and the required certificate.
Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.