Badger Meter TFX-5000
Badger Meter

TFX-5000 non-invasive ultrasonic clamp-on flow meter

Ultrasonic flowmeters

Manufacturer
Badger Meter
Model
TFX-5000
Instrument type
Ultrasonic flowmeters
Pipe sizes
15–1200 mm (1/2–48 in)
Flow range
2.32–125,000 l/min (0.7–33,000 gpm)
Accuracy
±0.5 % ±0.008 m/s (0.025 ft/s)
Repeatability
±0.2 %
Temperature range
−40 to 176 °C (−40 to 350 °F)
Mounting
clamp-on, non-invasive, no moving parts
Power supply
9–28 V DC; 20–26 V AC; 85–265 V AC
Communication
BACnet MS/TP, BACnet/IP, Modbus RTU, Modbus TCP, EtherNet/IP
Cloud connectivity
data platform connectivity
Approvals
CSA; BTL; MCERTS
Request a quote
Review enquiry

The TFX-5000 is a non-invasive ultrasonic clamp-on flow meter for liquids. It is designed for quick installation without cutting or tapping the pipe, and measures liquids including caustic substances, raw sewage and ultrapure water. Installation can be completed in under an hour by a single person.

The meter is attached to the outside of the pipe and does not penetrate it; the measurement is made with ultrasound transmitted through the pipe wall into the liquid. Because the meter has no moving parts and does not contact the medium, maintenance is minimal.

The TFX-5000 covers pipe sizes from 15 to 1200 mm (1/2 to 48 inches) and a flow range of 2.32 to 125,000 l/min (0.7 to 33,000 gpm). Accuracy is ±0.5 % ±0.008 m/s (0.025 ft/s) and repeatability ±0.2 %. The meter operates at temperatures from −40 to 176 °C (−40 to 350 °F).

The meter can be powered with 9–28 V DC, 20–26 V AC or 85–265 V AC. For data transfer it supports BACnet MS/TP, BACnet/IP, Modbus RTU, Modbus TCP and EtherNet/IP, and it offers connectivity to the manufacturer's data platforms. A flexible configuration is available to suit the installation.

The meter is certified by CSA, has BTL (BACnet Testing Laboratories) listing and holds MCERTS certification. Standards referenced for it are ISO 1648-6 and ISO 16484-6.

Applications listed for the TFX-5000 are HVAC systems, data centres, property operations, industrial processes, industrial wastewater and wastewater treatment, oil and gas, refining, chemical and petrochemical plants, test equipment and services, environmental monitoring, drinking water treatment and distribution network monitoring.

Please state the pipe size and material, the liquid, the flow range and temperature, and the required power supply and communication protocol in your enquiry.

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments