EDT 101
Temperature

RTD sensors
The TP23 is a compact and robust temperature sensor made of brass, with a Pt100 measuring element, designed for stick-in installation in protection tubes. It is used in shipbuilding and in rail and machine applications such as traction motors, gearboxes and wheelset bearings.
The sensor works on the Pt100 principle, in which the electrical resistance of the platinum element increases with temperature in a practically linear relationship. The measuring range is 0 to 200 °C, and the standard tolerance is class B; other accuracy classes are available on request. An NTC element can be supplied instead of the Pt100.
The sensor is clamped in the protection tube with a pressure screw. Because the protection tube stays in the process, the sensor can be replaced during operation. Matching protection tubes are the MX1 in brass and the MX6 in stainless steel. The immersion depth is 55 mm.
The cable is fixed to the sensor with a straight outlet and consists of a steel-braided PTFE cable with 2 × 0.75 mm² conductors. Cable lengths of 0.5 m, 2.3 m, 2.5 m, 6 m, 7.5 m and 8.0 m are offered, and versions are available in 2-wire or 4-wire connection. The sensor is rated IP68.
Relevant standards are DIN EN 60751 and IEC 751 for platinum resistance thermometers, DIN 89011, ISO 228/1 G1/2A for the thread and DIN 13 T5. The tolerance class is also stated with reference to DIN EN 60571. The sensor carries CE marking and a DNV approval for maritime applications.
Applications named are shipbuilding, traction motors, gearboxes, wheelset bearings and compressor and air conditioning systems. Assembly with the protection tube is simple. Please state the cable length, the 2-wire or 4-wire version, the accuracy class and whether a protection tube MX1 or MX6 is required in your enquiry.
Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.