EDT 101
Temperature

RTD sensors
TP31, TH31 and TH32 are stick-in temperature sensors with a polymer housing, designed to be inserted into protection tubes at the measuring point. They are offered for the shipbuilding industry and for machinery and equipment, measuring the temperature of cooling water and lube oil on engines and gearboxes. The sensors carry BV and DNV certificates.
The TP31 uses a Pt100 platinum measuring element whose resistance increases with temperature, in accordance with IEC 751 and DIN EN 60751. The TH31 and TH32 use NTC thermistors made of ceramic metal oxides, whose resistance falls as temperature rises.
The measuring range of the TP31 is 0 to 120 °C. The TH31 covers 40 to 120 °C and the TH32 0 to 70 °C. Standard immersion depths are 56 mm and 100 mm (TP31-01); 120 mm and 150 mm and customer-specific lengths are available on request. The sensors withstand pressures up to 40 bar. The insulation voltage is 500 VAC, with an insulation resistance above 10 MΩ at 500 VDC.
The sensor tube is stainless steel and the housing plastic, with a lateral cable outlet. Electrical connection is through a DIN 46244 tab connector (A6.3 × 0.8). The housing is protected to IP54; installed in a protection tube at the measuring point, IP68 is achieved. Storage temperature is −40 to +105 °C, and the sensor weighs approximately 70 g.
Two protection tubes are available. The MX2 is made of brass, weighs approximately 70 g and gives response times of t0.5 = 40 s and t0.9 = 120 s. The MX5 is made of stainless steel 1.4305, weighs approximately 100 g and gives t0.5 = 60 s and t0.9 = 150 s. The maximum flow velocity in water is 5 m/s. Installation is straightforward via the protection tube, so the sensor can be removed without opening the system.
The design follows DIN 89011 as well as IEC 751. Typical measuring points named are cooling water and lube oil circuits of engines and gearboxes in shipbuilding and in machinery.
When enquiring, please state the sensor type (TP31, TH31 or TH32), immersion depth and whether an MX2 or MX5 protection tube is needed.
TP31, TH31, TH32, TP31-01, MX2, MX5
Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.