VVB3
Mechanical & physical measurement

Vibration & condition monitoring
TX563x is a range of compact and robust vibration sensors (accelerometers) for heavy-duty industrial applications and hazardous environments. The sensors provide vibration condition monitoring of rotating machinery such as motors, pumps, gearboxes and compressors, and they are certified intrinsically safe for use in mining and in hazardous industrial areas.
The sensing principle is piezoelectric. A piezoelectric crystal is compressed by a seismic mass when the machine vibrates, and the resulting charge is processed on a signal conditioning board inside the housing. The sensors generate an output proportional to vibration and make it possible to detect imbalance, misalignment, bearing deterioration and structural resonance.
Two output types are available. TX5633 provides an ac signal of 100 mV/g (nominal at 80 Hz) with a frequency response of 1 Hz to 10 kHz and a mounted resonance of 18 kHz; it is supplied with 12 V DC. TX5634 to TX5639 provide a 4–20 mA signal and run on 10 to 32 V DC. TX5634-6 measure acceleration in ranges of 2, 5, 10, 20, 50 or 100 g RMS from 10 Hz to 5 kHz; TX5637-9 measure velocity in ranges of 20, 25, 50 or 100 mm/s RMS from 10 Hz to 1 kHz. The operating temperature range is −55 to +110 °C for TX5633 and −40 to +60 °C for the 4–20 mA models.
The housing is corrosion-resistant stainless steel of fully welded construction, rated IP67; connectors are rated IP65. The sensors are mounted with an M8 × 8 mm stud or a Quickfit bush (TX5633), or with an M8 × 12 mm or M10 × 10 mm stud or Quickfit bush (TX5634-9); the recommended mounting torque is 8 Nm. Electrical connection is by an integral screened and armoured cable, available in lengths such as 5 m, 10 m and 92 m, or by a 4-pin MS or M12 connector.
Intrinsic safety markings include Ex ia I Ma for mining, Ex ia IIC T6 or T4/T6 Ga for gas and Ex ia IIIC T80 °C or T130 °C/T80 °C Da for dust. The sensors are certified to ATEX and IECEx and hold EAC approval. Planned preventive maintenance with a check every three months and calibration every twelve months is recommended.
Listed applications are motors, pumps, gearboxes, compressors and other rotating machinery, tunnels, mining including underground coal mines, gas and coal dust environments and other potentially explosive atmospheres. Please specify the output type, measuring range, mounting and cable or connector version in your enquiry.
TX5633, TX5634, TX5635, TX5636, TX5637, TX5638, TX5639, TX5633.11, TX5633.12, TX5633.12.21, TX5633.11.22, TX5634.11, TX5635.12, TX5637.12.21, TX5638.11.22, TX5638.12.23, TX5630.11, TX5630.12, TX5630.13, TX5630.14
Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.