Trolex TX6355
Trolex

TX6355 Sentro Wireless gas detector for underground mines

Gas detectors & alarms

Manufacturer
Trolex
Model
TX6355
Instrument type
Gas detectors & alarms
Gases
CO (low and high level), methane, carbon dioxide, oxygen, other toxic gases
Sensing modules
pre-calibrated plug-in eModules, e.g. TX6350.04 250.50 (0–50 ppm), TX6350.04 250.500 (0–500 ppm)
Measuring range CO
0 to 50 ppm or 0 to 500 ppm
Sampling
diffusion
Wireless output
proprietary, via CommTrac network
Alarms
two adjustable set points, built-in visual alarms
Display
LCD with LED alarm indicators
Power
4 × alkaline D cells, 6 V DC; up to 45 days
Current consumption
200 mA max. (with one pellistor eModule)
Ex marking
Ex ia I Ma
Protection
IP65, reinforced polymer housing
Operating temperature
−20 to +40 °C, 95 % RH non-condensing
Weight
1.4 kg
Approvals
IECEx, MSHA, QPS, EAC, UL
Request a quote
Review enquiry

The TX6355 Sentro Wireless is a fixed-point gas detector for the safety monitoring of toxic and flammable gases in heavy-duty applications, in particular in underground gassy mines. It is also used in tunnelling, shale gas, underground storage areas, process plants and oil and gas, for fixed-location air monitoring.

The detector uses pre-calibrated plug-in Sentro eModules, each for a specific gas. Ambient gas reaches the sensor by diffusion, and the concentration is shown on the LCD. Data are transmitted over the CommTrac wireless network to a base node, which provides real-time concentration readings and alarm status. Two alarm set points are user adjustable, and built-in visual LED alarms operate when they are exceeded.

eModules are available for carbon monoxide at low and high levels, methane, carbon dioxide, oxygen and various other toxic gases. For carbon monoxide, the eModule TX6350.04 250.50 covers 0 to 50 ppm and the TX6350.04 250.500 covers 0 to 500 ppm.

The detector is battery powered by four alkaline D cells at 6 V DC and operates for up to 45 days. Current consumption is at most 200 mA with one pellistor eModule fitted. The wireless output signal is proprietary. The heavy-duty housing is made of reinforced polymer, rated IP65 and weighs 1.4 kg. It is suspended by an attachment point on top that accepts a standard 25 mm strap. Operating temperature is −20 to +40 °C at up to 95 % humidity non-condensing.

The detector is intrinsically safe with marking Ex ia I Ma for Group I mining. It complies with IEC 60079-0, IEC 60079-11, EN 60079-29-1, 30 CFR Part 18 and UL 61010-1. Versions are available as general purpose, EAC, MSHA, MSHA-QPS and IECEx Group I (Australia).

The cover screws must be tightened to 1.24 N·m (10 in·lb). The housing must not be opened when coal dust is present, and the detector should be inspected for damage if dropped.

Please state the gases and ranges to be monitored, the required approval version and the number of detectors in your enquiry.

Part numbers · 7

TX6355.00.01, TX6355.14.01, TX6355.04.01, TX6355.04.02, TX6355.06.01, TX6350.04 250.50, TX6350.04 250.500

Industry applications

Selection notes

Identify the target gas, background gas and concentration units. State whether the sampling system is already installed or belongs in the enquiry.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU