LDH313
Gas analysis

Gas detectors & alarms
TX6373 is a fixed gas detector and transmitter for toxic gases and oxygen in hazardous areas. It is intrinsically safe and approved for Group I, mining, and for Group II surface industries, and it is used where personnel must be protected from toxic gas exposure in tunnels, mines, plants and underground facilities.
The detector uses high-accuracy electrochemical sensing elements. Each gas is measured by a pre-calibrated plug-in sensing module with a standardised output, so a module can be exchanged on site without recalibrating the transmitter, which shortens maintenance. Modules are available for carbon monoxide, hydrogen sulphide, sulphur dioxide, hydrogen, ammonia, nitrogen dioxide, chlorine, nitric oxide and oxygen. For measuring points that are difficult to reach, the sensing module can be mounted remotely from the transmitter (TX6373.84 versions).
The transmitter conditions the sensor signal and sends it to the monitoring system as 4–20 mA, 0.4–2 V or 5–15 Hz, depending on the version and the system used. It can be wired as a 2- or 3-wire loop or as a 4-wire powered device. Group I versions are supplied with 12 V DC, Group II and general-purpose versions with 24 V DC. Zero and span calibration is carried out with push buttons, and the output is frozen during calibration in 4-wire systems to prevent false alarms. A graphic LCD with backlight shows gas concentration and status.
The detector holds SIL 1 and SIL 2 accreditations for use in safety instrumented functions, as well as ATEX and other national approvals. The housing is made of anti-static polycarbonate/ABS, withstands an impact of 20 joules and is rated IP65, with IP54 at the gas inlet. Three M20 cable entries and 4 mm barrier terminals simplify wiring. The device operates from −10 to +50 °C at up to 90 % RH non-condensing and weighs 450 g.
Typical applications are mining and tunnelling, offshore platforms, petrochemical processing, manufacturing and process plants, storage areas and warehouses, water and sewage treatment, power generation, gas storage and distribution and telecommunications. Please specify the gas, measuring range, hazardous area group, output signal and whether a remote sensing module is required.
TX6373.01, TX6373.02, TX6373.03, TX6373.84.01, TX6373.84.02, TX6373.84.03, TX6373.01.12, TX6373.84.01.12, TX6373.02.12, TX6373.84.02.12, TX6373.01.11, TX6373.01.13
Identify the target gas, background gas and concentration units. State whether the sampling system is already installed or belongs in the enquiry.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.