Trolex TX9042
Trolex

TX9042 programmable sensor controller for mining and hazardous areas

Process & PID controllers

Manufacturer
Trolex
Model
TX9042
Instrument type
Process & PID controllers
Inputs
8 analogue or digital channels, or 16 on/off inputs, via plug-in modules
Input modules
DC analogue, AC (RMS) analogue, digital, fail-safe digital, thermocouple, Pt100, strain gauge, flow, RS-485 comms
Output relays
4 encapsulated reed relays; 2 setpoints per channel plus fault
Relay rating
23 V, 0.25 A, 3 W max. (intrinsically safe circuits only)
Setpoint / display accuracy
±0.5 % / ±0.25 % (analogue channels)
Display
LCD, 4 lines × 20 characters, 6 mm high
Programming
4-key keypad, no software required
Communication
RS-485 Modbus, up to 32 units per network
Data logging
up to 26,000 readings
Supply
12 V DC +20 %/−2.5 % at 125 mA; Ui 16.5 V
Ex marking
Ex ia I Ma (mining version)
Ex parameters
Uo 16.5 V, Io 242 mA, Po 1 W, Co 300 µF, Lo 100 mH
Ambient temperature
−10 to +50 °C; Ex: −20 °C ≤ Ta ≤ +40 °C
Housing
ABS, DIN rail; IP54 in metal enclosure
Approvals
ATEX, IECEx, ANZEx, MASC, EAC, MSHA; SIL 1 and SIL 2 (IEC 61508)
Request a quote
Review enquiry

The TX9042 is a programmable sensor controller (PSC) for managing sensors and data communications in arduous industrial and hazardous environments. It is designed specifically for mining and tunnelling and is offered as a general purpose version and as an intrinsically safe mining version marked Ex ia I Ma for methane and coal dust atmospheres.

The controller accepts up to eight analogue or digital inputs, or up to sixteen on/off inputs, through interchangeable plug-in modules. Available modules cover DC analogue current and voltage signals, AC (RMS) analogue signals such as vibration, digital and fail-safe digital inputs including NAMUR switches, thermocouples, Pt100 sensors, strain gauges, flow sensors, RS-485 and digital communications, as well as output modules for on/off states, relay contacts and 4–20 mA. Signals from 2-wire, 3-wire and 4-wire current loop devices and voltage inputs can be connected.

Functions are programmed directly with a four-key keypad, with no special software required. Each channel has two setpoints plus a fault signal, and four encapsulated reed relays switch alarms and trips; relay contacts are rated 23 V, 0.25 A and 3 W maximum in intrinsically safe circuits. Setpoint accuracy is ±0.5 % and display accuracy ±0.25 % on analogue channels. The 20-character, four-line LCD with 6 mm characters shows channel close-up data. Up to 26,000 readings can be logged.

Up to 32 units can be connected to a mine-wide system over RS-485 using the Modbus protocol. The supply is 12 V DC (+20 %/−2.5 %) at 125 mA; Ex parameters include Ui 16.5 V, Uo 16.5 V, Io 242 mA, Po 1 W, Co 300 µF and Lo 100 mH.

The ABS housing is DIN-rail mounted and weighs 800 g. For intrinsically safe use it must be installed in a protective metal enclosure with IP54 protection, by competent personnel. Ambient limits are −10 °C to +50 °C, and −20 °C to +40 °C for the Ex version. Certification includes ATEX, IECEx, ANZEx, MASC, EAC and MSHA (30 CFR Part 18), and the controller is suitable for SIL 1 and SIL 2 applications according to IEC 61508.

Listed applications include underground machinery protection, environmental monitoring, gas detection systems, conveyor control, pump, compressor and fan monitoring, machine condition monitoring, plant protection and data collection from groups of diverse sensors in gassy underground and coal mines.

Please state the required version, the number and type of sensors and the communication system when enquiring.

Part numbers · 34

TX9042.55, P5423.516, P5423.508, P5423.514, P5423.509, P5423.515, P5423.552, P5423.553, P5423.556, P5423.510, P5423.513, P5423.528, P5423.518, P5423.506.01, P5423.506.02, P5423.523, P5423.522, P5423.524, P5423.520.01, P5423.520.02, P5423.520.03, P5423.520.04, P5423.520.05, TX9204, TX2101.3.100, TX2102.3.200, TX2141.3.307, TX2141.3.309A, TX2141.3.309V, TX2141.3.501, TX2141.3.504, TX2141.3.603, TX2141.3.604, TX2141.3.701

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments