Type 8189
Level

Ultrasonic level transmitters
The UCL-520 is a two-wire ultrasonic continuous level transmitter for non-contact level measurement. It is designed for challenging media such as ultra-pure liquids, corrosive liquids and waste liquids.
The transmitter uses ultrasonic technology: it measures the distance to the liquid surface and converts it into a level signal. Automatic temperature compensation over the full range corrects the measurement for changes in temperature. The output is a 4–20 mA signal in a two-wire loop; the maximum loop resistance is 500 Ω at 24 V DC.
Depending on the model, the maximum range is from 6 feet to 26.2 feet (up to 7.98 m), and the resolution is 0.039 in, approximately 1 mm. The loop fail-safe behaviour is selectable: the output can go to 4 mA, 20 mA, 21 mA or 22 mA, or hold the last value.
Ambient temperature may range from −40 to 160 °F (−40 to 71 °C), and the permitted pressure is 30 psi at 25 °C. Wetted and housing materials are PX/ABS FR, PVDF and Viton; the stem and mounting are made of PVDF. The process connection is a 2 in NPT thread, which allows easy installation. A shielded cable is recommended in areas with high electrical noise.
The transmitter is described as easy to install, with limited mounting options. Options include standpipe mounting for pipes of 1 in to 6 in diameter, a relay output with a mechanical dry contact and a FET output with a solid-state switch. The article number listed for this transmitter is 225200.
Applications named are ultra-pure liquids, corrosive liquids, waste liquids and standpipe applications from 1 in to 6 in diameter. Please send the tank height, the liquid, the mounting arrangement and any switching output required with your enquiry.
225200
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.