Surent G480
Flow

Coriolis flowmeters
UMC3 is the transmitter for a family of Coriolis mass flow meters, series TM, TME, TMU and TMR. It drives the measuring tubes of the sensor into oscillation through an excitation coil, picks up the measuring signal proportional to the mass flow, compensates it for temperature and converts it into analogue, pulse and digital outputs. Besides mass flow, the transmitter provides volume flow, density and temperature of the medium.
The measuring system is suitable for liquids and gases in pipelines; with matching sensors, accuracy of ±0.1 % for liquids and ±0.5 % for gases is achieved, and custody transfer applications are possible. The transmitter has two 0/4–20 mA analogue outputs, an active 24 V binary output for up to 200 mA, a passive optocoupler binary output, a status output and a frequency output up to 1 kHz for totalisers. Response time is below 20 ms.
Digital communication is available via HART, Profibus PA, Profibus DP, Modbus RTU with baud rates from 1200 to 38,400 Bd, or Foundation Fieldbus. Configuration is done with the built-in control and display unit, so a separate handheld terminal is not needed; the display unit can also be installed separately. A plug-in data memory module stores the sensor and configuration data, and the electronics can be replaced in the field without recalibration.
The housing has two compartments, separating electronics and terminals, and is rated IP68. For hazardous areas the transmitter is available in increased safety and flameproof versions, marked II (1)2G Ex de[ia] or Ex d[ia] IIC/IIB T6–T3, with intrinsically safe sensor circuits, as well as intrinsically safe fieldbus versions to the FISCO model. ATEX and NEPSI approvals are available, and a special version allows ambient temperatures up to 80 °C in the hazardous area. The transmitter is mounted directly on the sensor or remotely with a connection box, with NPT or M20 cable entries.
Power supply options are 19–36 V DC, 24 V AC and 90–265 V AC. Typical applications are mass flow and density measurement in the chemical industry, food and beverage production with viscous media such as molasses and pastes, paints and varnishes, and custody transfer of liquids and gases. Please specify the sensor, power supply, outputs and Ex requirements.
UMC3, UMC.2, UMC.2A, UMC.2B, UMC3-PA, UMC3-Modbus, UMC3-FF
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.