Coriolis flowmeters
UMC4 is a programmable transmitter for Coriolis mass flow sensors (types TM, TME, TMR, TMU, TM-SH and HPC). This version is supplied in a rack mount housing for remote installation in a rack or enclosure, separate from the sensor in the pipeline. It provides real-time values of mass flow, volume flow, density and temperature.
In a Coriolis meter, an excitation coil makes the flow tubes oscillate, and pick-up coils detect the measuring signal, which is proportional to the mass flow because of the Coriolis force acting on the moving medium. The UMC4 regulates the sensor vibration, processes the signals instantaneously, compensates them for temperature and converts them into analogue and digital outputs. Functions include adaptive flow optimisation and intelligent diagnostics, and a display is built in.
The rack version is powered with 19 to 36 V DC. It has two passive 4–20 mA outputs, one of them with HART, passive binary outputs via optocoupler (Ui = 30 V, Ii = 50 mA, Pi = 0.5 W) for pulse and status, a 1 kHz frequency output and a second pulse output phase-shifted by 90°. Communication options include HART, Modbus RTU and PROFIBUS PA or DP; RS-232 and USB interfaces are also listed.
The rack mount version is protected to IP20 and must be installed inside an enclosure of at least IP54 that is ATEX-certified where required. It operates at ambient temperatures from −20 to 60 °C and weighs about 1 kg. The transmitter family also includes field housings for integral or remote mounting (about 2.4 kg, 3.5 kg with pipe/wall mounting and junction box), panel mount versions and explosion-proof single-compartment versions marked II (1)2G Ex d [ia Ga] IIC T4-T3 Gb. Approvals include ATEX, IECEx, NEPSI, KC, DNV and OIML R139 for custody transfer.
Cable glands are not included, and the operator must provide suitable glands for Ex protection. Installation and servicing must be carried out by qualified personnel with the device completely de-energised.
Listed applications are hydrogen refuelling stations, chemical industry, oil and gas, food and beverage, custody transfer and hazardous locations, for liquids, gases, chemical fluids and suspensions. Please tell us the sensor type, required outputs and communication protocol in your enquiry.
UMC4-RM, UMC4
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.