DwyerOmega V20
DwyerOmega

V20 remote reading vapour-actuated dial thermometer

Dial thermometers

Manufacturer
DwyerOmega
Model
V20
Instrument type
Dial thermometers
Principle
vapour-actuated, Bourdon tube with geared movement
Measuring range
−40 to 450 °F
Accuracy
±1 scale division
Scale
°F, °C
Dial sizes
2", 2½" and 3½"
Ambient temperature
−40 to 60 °C (−40 to 140 °F)
Sensing bulb
nickel-plated copper, Ø 7/16"
Capillary
tin-plated copper, 60" standard, up to 1200"; PVC-coated, bronze braided or 316 SS options
Case material
300 series stainless steel; ABS plastic or aluminium options
Window
polycarbonate
Bourdon tube / movement
phosphor bronze / brass with precision gearing
Connections
plain; ½" NPT union; ½" NPT union with extension; thermowell
Mounting
flush front flange, U-clamp
Standard / approval
ASME B40.200; NSF
Request a quote
Review enquiry

The V20 series are remote reading dial thermometers for indicating temperature at locations that are hard to access. The sensing bulb is placed in the medium, while the dial is mounted where it can be read easily, connected to the bulb by a capillary. Because the system is vapour actuated, the effect of ambient temperature on accuracy is kept to a minimum.

The sensing bulb is connected via capillary tubing to a Bourdon tube, which drives the pointer through a brass movement with precision gearing. The bulb contains a liquid whose vapour pressure depends only on the temperature at the bulb. Being vapour actuated, the thermometer has a progressively graduated scale, and the reading is not affected by ambient temperature variations along the capillary and the case.

The measuring range extends from −40 to 450 °F, with scales in °F and °C. Accuracy is ±one scale division. The permitted ambient temperature for the dial is −40 to 60 °C (−40 to 140 °F). Dial sizes of 2", 2½" and 3½" are available, with a dial depth of 1.09 in.

The sensing bulb is made of nickel-plated copper with a diameter of 7/16". The standard capillary is 60" of tin-plated copper; lengths up to 1200" are possible, and PVC-coated, bronze-braided and 316 stainless steel capillaries are available. The case is 300 series stainless steel as standard, with ABS plastic and aluminium as alternatives, and the window is polycarbonate. The Bourdon tube is phosphor bronze. Connections include a plain bulb, a ½" NPT union, a ½" NPT union with extension and a ½" NPT thermowell; mounting is by flush front flange or U-clamp.

Options include strain relief, silicone dampening, a lens O-ring, case sealant, a weep hole and over-range protection. The series refers to ASME B40.200 and carries an NSF listing. The sensing bulb and the case should be installed at a similar height; for bulb lengths and capillaries longer than 1200" a special configuration is required.

Stated applications are the food service industry, industrial processing, refrigeration and commercial dishwashing. Please send the temperature range, dial size, capillary length and material and the required connection and mounting.

Part numbers · 16

V2036, V3537L, V2066, V2567L, DW25B, DW25316, DW40B, DW40316, DW60B, DW60316, DW25B-75, DW25316-75, DW40B-75, DW40316-75, DW60B-75, DW60316-75

Industry applications

Selection notes

Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU