The VA6530A is a portable non-contact digital infrared thermometer with a laser sight, intended for fast and safe surface temperature measurement in industry, power engineering, construction, machinery maintenance and electrical installations.
An infrared thermometer measures the thermal radiation emitted by a surface and converts it into a temperature reading. Because different materials radiate differently, the emissivity of the VA6530A can be set from 0.10 to 1.00 to match the target surface. A single-point laser sight (Class II, below 1 mW, 630–670 nm) shows where the instrument is aimed.
The measuring range is −40 °C to +537 °C (−40 °F to +999 °F), with an accuracy of ±(1 % of reading + 2 °C). The distance-to-spot ratio is 12:1, which means that at a distance of 12 units the measured spot has a diameter of one unit; the maximum measuring distance is 1.5 m.
The dual backlit LCD shows the main value with 13 mm digits and a secondary value with 9.2 mm digits. Besides the current reading, the thermometer displays the MAX, MIN and AVG values and the MAX−MIN difference. High and low temperature alarms give audible and visual indication when a set limit is exceeded, so a series of measuring points can be checked and any value outside the permitted band is signalled immediately. The reading is held automatically, and the device switches off after 10 seconds to save the battery.
Listed applications are industrial applications, power engineering, construction, maintenance of machinery and electrical installations.
In summary, the VA6530A combines a −40 °C to +537 °C range, a 12:1 optic with laser aiming, adjustable emissivity, statistical values and alarms in one portable instrument.
Please state the required quantity and the temperature range of your application when requesting a quotation.
VA6530A
Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.