NORIS Group GmbH VF5..KD
NORIS Group GmbH

VF5..KD frequency transducer with wheel/tyre wear correction

Signal conditioners & barriers

Manufacturer
NORIS Group GmbH
Model
VF5..KD
Instrument type
Signal conditioners & barriers
Input
square-wave frequency from speed sensors
Input ranges
10–100 Hz, 20–1,000 Hz, 200–10,000 Hz (range codes 00, 01, 02)
Wear correction
wheel/tyre diameter set on sealed, tamper-evident drum scale
Output signal
0–10 V (G1), 2–10 V (G2), 0–20 mA (I1), 4–20 mA (I2)
Voltage output
short-circuit proof, max. 20 mA
Current output load
0–500 Ω
Supply voltage
9–32 VDC
Isolation
galvanic, input to output
Connection
DIN EN 46244 tab connector A6.3 × 0.8, gold-plated
Mounting
TS32 G-rail or TS35 top-hat rail
Housing
thermoplastic polyester, fire class V0
Operating temperature
−20 to +70 °C
Weight
55 g
Standards, approvals
DIN EN 50155, EN 50121-3-1/-2/-3; DNV, BV, LR
Request a quote
Review enquiry

The VF5..KD is a measuring transducer that converts square-wave frequency signals from speed sensors into standardised voltage or current outputs and, in addition, corrects for wheel or tyre wear. It is designed for transport technology and rail vehicles, where the speed derived from wheel rotation changes as the running surface wears.

As the wheel or tyre wears, its diameter decreases, so the same vehicle speed produces a higher rotational frequency. On the VF5..KD the actual wheel or tyre diameter is set on a sealed drum scale. The transducer takes this diameter into account and converts the input frequency into a proportional output signal that reflects the true speed despite tread wear. The drum scale is tamper-evident, so that unauthorised changes can be detected. Input and output are galvanically isolated, and an integrated LED shows the operating status.

Three input ranges are available, identified by the codes 00, 01 and 02: 10–100 Hz, 20–1,000 Hz and 200–10,000 Hz. Tyre diameter setting codes complete the type designation. The output is 0–10 V (G1), 2–10 V (G2), 0–20 mA (I1) or 4–20 mA (I2). Voltage outputs are short-circuit proof with a load current of up to 20 mA, and current outputs drive loads of 0 to 500 Ω. Examples of article numbers are VF500KDx-G1, VF502KDx-I2 and VF501-KD99-I2.

The transducer operates from 9 to 32 VDC. Connection is by gold-plated DIN EN 46244 tab connectors (A6.3 × 0.8), and the compact 55 g housing snaps onto TS32 G-rail or TS35 top-hat rail. The housing is thermoplastic polyester to fire protection class V0. The operating temperature range is −20 to +70 °C.

The device complies with DIN EN 50155 for railway electronics and with the railway EMC standards DIN EN 50121-3-1, -3-2 and -3-3, as well as DIN EN 61000-6-2 and -6-4, IEC 61000-4-2 to -6 and the environmental tests of IEC 60068. Class approvals from GL/DNV, BV and LR are listed.

When enquiring, please state the input range, output signal, sensor pulses per revolution and the wheel diameter range to be set.

Part numbers · 13

VF500KDx-G1, VF501KDx-G1, VF502KDx-G1, VF500KDx-G2, VF501KDx-G2, VF502KDx-G2, VF500KDx-I1, VF501KDx-I1, VF502KDx-I1, VF500KDx-I2, VF501KDx-I2, VF502KDx-I2, VF501-KD99-I2

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.