NORIS Group GmbH VFW5
NORIS Group GmbH

VFW5 transducer for the W terminal frequency of a 24 V three-phase generator

Signal conditioners & barriers

Manufacturer
NORIS Group GmbH
Model
VFW5
Instrument type
Signal conditioners & barriers
Input
terminal W of a 24 V three-phase generator
Input ranges
0–100 Hz (VFW500), 0–1,200 Hz (VFW501)
Output signal
0–10 V (G1), 2–10 V (G2), 0–20 mA (I1), 4–20 mA (I2)
Voltage output
short-circuit proof, max. 20 mA
Current output load
0–500 Ω
Error class
1.5 % (IEC 51-1)
Reaction time
0.25 s at 50 Hz; 0.2 s at 100 Hz; 0.1 s at 1 kHz; 50 ms at 10 kHz
Supply
24 VDC via terminal W, approx. 50 mA
Isolation
galvanic, input to output
Connection
DIN EN 46244 tab connector A6.3 × 0.8, gold-plated
Mounting
TS32 G-rail or TS35 top-hat rail
Housing
thermoplastic polyester, fire class V0
Operating temperature
−20 to +70 °C
Weight
55 g
Approvals
DNV, BV, LR
Request a quote
Review enquiry

The VFW5 is a measuring transducer that converts the frequency signal from a 24 V three-phase generator into a standardised output signal. It is designed for marine applications, machine controllers and harsh environments, and carries the class approvals of DNV, LR and BV.

The input is taken from terminal W of the generator. This terminal delivers a pulsating DC voltage whose frequency is related to generator speed. The VFW5 evaluates this frequency and converts it into a proportional standard voltage of 0–10 V or 2–10 V, or a standard current of 0–20 mA or 4–20 mA. The transducer is supplied with 24 VDC via terminal W of the generator and draws approximately 50 mA. Input and output are galvanically isolated.

Two input ranges are available: 0–100 Hz (VFW500) and 0–1,200 Hz (VFW501). Combined with the four output versions G1 (0–10 V), G2 (2–10 V), I1 (0–20 mA) and I2 (4–20 mA), this gives eight articles from VFW500-G1 to VFW501-I2. Voltage outputs are short-circuit proof with a load current of up to 20 mA; current outputs drive loads of 0 to 500 Ω. The error class is 1.5 % according to IEC 51-1. Reaction time depends on frequency: 0.25 s at 50 Hz, 0.2 s at 100 Hz, 0.1 s at 1 kHz and 50 ms at 10 kHz.

An integrated LED shows the operating status, and the range can be fine-adjusted with a sealed trimming potentiometer. Connection is made with gold-plated DIN EN 46244 tab connectors (A6.3 × 0.8). The compact 55 g housing allows side-by-side mounting on TS32 G-rail or TS35 top-hat rail and is made of flame-inhibiting thermoplastic polyester to fire protection class V0. The operating temperature range is −20 to +70 °C.

The transducer is tested to IEC 60068 for vibration, shock and damp heat, to IEC 61000-4-2 to -6 and EN 61000-6-2/-4 for EMC, and conforms to DIN EN 50155.

When enquiring, please state the input range and output signal, or the article number, and the generator data.

Part numbers · 8

VFW500-G1, VFW501-G1, VFW500-G2, VFW501-G2, VFW500-I1, VFW501-I1, VFW500-I2, VFW501-I2

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU