NORIS Group GmbH VTK5
NORIS Group GmbH

VTK5 rail-mounted transducer for type K thermocouples

Temperature transmitters

Manufacturer
NORIS Group GmbH
Model
VTK5
Instrument type
Temperature transmitters
Input
thermocouple type K (NiCr-Ni) to EN 60584-1
Input ranges
0–600 °C (VTK58), 0–800 °C (VTK59)
Output signal
0–10 V (G1), 2–10 V (G2), 0–20 mA (I1), 4–20 mA (I2)
Voltage output load
short-circuit proof, max. 20 mA
Current output load
max. 500 Ω
Cold junction
integrated reference junction
Monitoring
broken-wire monitoring, status LED
Supply voltage
9–32 VDC, galvanically isolated from input
Connection
DIN EN 46244 tab connector A6.3 × 0.8, gold-plated
Mounting
TS32 G-rail or TS35 top-hat rail
Housing
thermoplastic polyester, fire class V0
Operating temperature
−20 to +70 °C, humidity max. 96 %
Dimensions, weight
70 × 46 × 17.5 mm, 55 g
Approvals
DNV, BV, LR
Request a quote
Review enquiry

The VTK5 is a measuring transducer that converts the signal of a NiCr-Ni type K thermocouple to EN 60584-1 into a standardised voltage or current output. The series is designed for marine applications, harsh environments and machine controllers, and it carries the shipbuilding approvals of DNV, BV and LR.

The device measures the temperature-dependent thermovoltage of the connected thermocouple. An integrated reference junction performs cold-junction compensation, and the signal is converted into an output proportional to the input. Sensor input and supply voltage are galvanically isolated. Broken-wire monitoring detects an interrupted thermocouple circuit, an integrated LED shows the operating status, and a sealed integrated trimming potentiometer allows fine adjustment.

Two input ranges are available: 0–600 °C (VTK58) and 0–800 °C (VTK59). Each is supplied with one of four outputs: 0–10 V (G1), 2–10 V (G2), 0–20 mA (I1) or 4–20 mA (I2). The voltage outputs are short-circuit proof with a maximum load current of 20 mA, and the current outputs accept a load of up to 500 Ω. The resulting article numbers are VTK58-G1, VTK58-G2, VTK58-I1, VTK58-I2 and the corresponding VTK59 versions.

The supply voltage range is 9 to 32 VDC. Electrical connection is by gold-plated DIN EN 46244 tab connectors (A6.3 × 0.8). The compact housing of 70 × 46 × 17.5 mm and 55 g is designed for side-by-side mounting on TS32 G-rail or TS35 top-hat rail. It is made of flame-inhibiting, self-extinguishing thermoplastic polyester to fire protection class V0. The permitted operating temperature is −20 to +70 °C at a maximum humidity of 96 %.

The transducer is tested to the vibration, shock and damp-heat tests of IEC 60068, the EMC standards IEC 61000-4-2 to -6 and EN 61000-6-2/-4, and to DIN EN 50155. Protection is to DIN EN 60529.

When enquiring, please state the input range (0–600 or 0–800 °C) and the output signal, or quote the article number directly.

Part numbers · 8

VTK58-I2, VTK58-G1, VTK59-G1, VTK58-G2, VTK59-G2, VTK58-I1, VTK59-I1, VTK59-I2

Industry applications

Selection notes

Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.