Z-10-D-IN 10-channel digital input module with counters, Modbus RTU

I/O modules

Manufacturer
SENECA
Model
Z-10-D-IN
Instrument type
I/O modules
Inputs
10 optically isolated channels, common negative
Sensor types
reed, proximity, PNP, NPN, dry contact
Sensor supply
internal 16 V DC
Switching thresholds
closed: >12 V DC and >3 mA; open: <10 V DC and <2 mA
Counters
up to 10 × 32-bit, max. 2.5 kHz
Input protection
TVS, transients up to 600 W/ms
Input filter
configurable
Memory
FeRAM, non-volatile
Communication
2-wire RS485, Modbus RTU slave
Isolation
1500 V AC
Power supply
10–40 V DC or 19–28 V AC, 50–60 Hz
Power consumption
typ. 1.5 W, max. 2.5 W
Dimensions
17.5 × 100 × 112 mm
Mounting
35 mm DIN 46277 rail; IDC10 rail bus connector
Operating temperature
−20 to +65 °C (−10 to +55 °C UL)
Request a quote
Review enquiry

The Z-10-D-IN is a digital input module of the Z-PC series. It acquires ten single-ended digital signals and makes their states, counts and timing available over an RS485 bus with the Modbus RTU slave protocol. The module is intended for industrial automation and process control and holds a RINA marine type approval.

The ten inputs are optically isolated with a common negative and accept reed contacts, proximity switches, PNP and NPN sensors and dry contacts. An internal 16 V auxiliary supply powers the connected sensors, so no external sensor supply is needed. An input is recognised as closed above 12 V DC and 3 mA, and as open below 10 V DC and 2 mA. Each input is protected by a TVS against transients up to 600 W/ms, and a digital input filter can be configured.

Besides the input states, the module measures frequency, period, ON time and OFF time. Up to ten 32-bit totalisers count pulses up to 2.5 kHz; they can count up or down and indicate overflow. Count values are stored in non-volatile FeRAM memory, so they are retained when power is lost. Configuration is made by DIP switches or through Modbus registers, and all data is read from Modbus registers.

The module is powered with 10–40 V DC or 19–28 V AC at 50–60 Hz, consumes typically 1.5 W and at most 2.5 W, and requires a Class 2 power supply and a fuse of no more than 2.5 A. Isolation is 1500 V AC. The RS485 interface is also available through an IDC10 connector on the rear of the module for the DIN 46277 rail bus.

The housing measures 17.5 × 100 × 112 mm, is rated IP20 and mounts on a 35 mm DIN rail to IEC EN 60715. Operating temperature is −20 to +65 °C, or −10 to +55 °C for the UL rating. The module carries UL and RINA approvals and complies with the EMC and Low Voltage Directives, RoHS and REACH, EN 61000-6-2, EN 61000-6-4 and EN 61010-1.

Versions Z-10-D-IN-1 and Z-D-IN-1 are listed in the same family. Accessories include rail bus connectors Z-PC-DINAL2-17.5, Z-PC-DIN2-17.5 and Z-PC-DIN8-17.5 and programming cables and adapters K107USB, S107USB and S117P1. Fields of use given for the module include water treatment, data acquisition, energy and renewables, chemical and pharmaceutical plants and marine applications. Please state the number of modules and the required accessories in your enquiry.

Part numbers · 3

Z-10-D-IN, Z-10-D-IN-1, Z-D-IN-1

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU