Fluke 1502A / 1504
Fluke

1502A / 1504 precision thermometer readout for PRT and thermistor probes

Temperature calibrators

Manufacturer
Fluke
Model
1502A / 1504
Instrument type
Temperature calibrators
Probes
1502A: 10–100 Ω RTD, PRT, SPRT; 1504: thermistors
Temperature range
1502A: −200 to 962 °C; 1504: any thermistor range
Resistance range
1502A: 0–400 Ω; 1504: 0–1 MΩ; auto-ranging
Accuracy
1502A: up to ±0.006 °C; 1504: up to ±0.002 °C
Resolution
1502A: 0.001 °C; 1504: 0.0001 °C
Measurement period
1 s
Characterisations
ITS-90, IPTS-68, Callendar–Van Dusen
Digital filter
exponential, 0–60 s
Probe connection
4-wire with shield, 5-pin DIN
Communication
RS-232 standard; IEEE-488 (GPIB) optional
Display
8-digit, 7-segment yellow-green LED, 0.5 in characters
Power
115 or 230 V AC ±10 %, 50/60 Hz, 1 A nominal; 12 V DC option
Operating temperature
1502A: 16–30 °C; 1504: 13–33 °C
Size, weight
61 × 143 × 181 mm (H × W × D), 1.0 kg
Request a quote
Review enquiry

The 1502A and 1504 are compact precision thermometer readouts for laboratory and field calibration. They provide a cost-effective, high-accuracy digital display for platinum resistance thermometers and thermistors: the 1502A is designed for RTDs, PRTs and SPRTs with a nominal resistance of 10 Ω to 100 Ω, the 1504 for thermistors.

Both instruments measure the resistance of the connected probe and convert it into temperature. A four-wire connection with shield on a 5-pin DIN connector eliminates the effect of lead resistance. The 1502A auto-ranges from 0 to 400 Ω and covers −200 to 962 °C; the 1504 auto-ranges from 0 to 1 MΩ and covers any thermistor range. The excitation current is adjustable to minimise self-heating of the sensor. Characterisation coefficients can be entered according to ITS-90, IPTS-68 or Callendar–Van Dusen, and an exponential digital filter from 0 to 60 s smooths the reading.

Accuracy is up to ±0.006 °C for the 1502A and up to ±0.002 °C for the 1504, with a resolution of 0.001 °C and 0.0001 °C respectively. The measurement period is one second. Values appear on an 8-digit, 7-segment yellow-green LED display with 0.5-inch characters, and critical parameters can be protected by a password.

An RS-232 serial interface is standard, and IEEE-488 (GPIB) is available as an option. The readouts run on 115 V AC or 230 V AC ±10 %, 50/60 Hz, 1 A nominal; a 12 V DC power option and the 9313 battery pack are available for field use.

The housing measures 61 × 143 × 181 mm (H × W × D) and weighs 1.0 kg. Rated operating temperature is 16 to 30 °C for the 1502A and 13 to 33 °C for the 1504; the instruments are for indoor use at altitudes below 2000 m. Referenced standards include IEC 1010-1, ITS-90, IPTS-68, IEC 751, DIN 43760 and IEEE Std 488.1; CE and C-TIC marks are listed.

Versions are the 1502A and 1504 with RS-232, the 1502A-156 standard PRT readout, and the 1502A-2506 and 1504-2506 with IEEE-488. Applications are temperature calibration, laboratory metrology, field calibration and industrial processes.

Please state the model, the probe type, the supply voltage and whether IEEE-488 or the battery option is required.

Part numbers · 5

1502A, 1504, 1502A-156, 1502A-2506, 1504-2506

Industry applications

Selection notes

Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU