EDT 96
Pressure

Pressure transmitters
The 3500 series is a compact, low-pressure OEM pressure transmitter with all wetted parts in 316L stainless steel. It is designed for applications where space is limited and high performance is required, such as OEM equipment, battery-powered remote installations and other space-constrained environments.
The sensor uses MMS technology, which lets it reach full accuracy quickly after power-up. This minimises stabilisation time and power draw, an advantage when the transmitter is switched on only for a measurement, as in battery-powered installations. Response time is 1.5 ms or less, and the fatigue life exceeds 100 million pressure cycles.
Pressure ranges extend from 0–5 to 0–600 psi (0–0.35 to 0–40 bar). Accuracy is 0.25 % of full scale, and long-term drift is less than 0.2 % of full scale per year. Proof pressure is twice and burst pressure three times the full scale. The transmitter operates from −40 to +125 °C and is temperature compensated from 0 to +100 °C.
A wide selection of electrical outputs is available: 4–20 mA current and 0.5–4.5 V, 0–5 V, 0–10 V and 1–6 V voltage signals. Pressure ports include 1/8-27 NPT, 1/4-18 NPT, 7/16-20 UNF, G 1/4, G 1/8 and M12, and electrical connections include DIN, M12, Deutsch and Packard connectors, so the transmitter can be adapted to the equipment without modification. Optional restrictors are offered for the pressure port.
The enclosure is rated IP67, and the transmitter weighs only 35 to 53 g. It carries CE, PED, RoHS and UR marks and is tested for EMC to EN 61326-1 and EN 61326-2-3 and for vibration and shock to BS EN 60068-2-6, -2-64 and -2-27. Installation requires a deep socket for the 22 mm hex; tightening torque depends on the fitting type.
Order codes such as 3500S030PA02B000 or 3500B100PG02K000 define range, pressure reference, output and connections. Please send the pressure range, pressure reference, output signal and preferred pressure and electrical connections with your enquiry.
3500S030PA02B000, 3500B015PV02B000, 3500S200PG01B000, 3500B100PG02K000, 3500B0016G02G000, 3500B0004G02GR00, 3500B300PG02E000, 3500B200PG02K000, 3500H400PG02K000, 3500B05P0G02K000, 3500R100PG02K000, 3500R030PG08E000, 3500S05P0V1JE000, 3500B0006G01K000, 3500B030PV02B000, 3500B350MG01B000, 3500B030PG02E000, 3500T600PG02B000, 3510B200PG02G000, 3500S100PG1JE000, 3500R0010G02K000, 3500B200PG02G000, 3500B0040V02B000, 3500R030PG02B000, 3510B100PG02G000
Specify whether the reference is gauge, absolute or differential pressure. Include the normal span and the largest pressure the instrument may see.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.