HORIBA 3552-10D
HORIBA

3552-10D slim submersible conductivity cell with temperature sensor, K = 1 cm⁻¹

Conductivity & resistivity sensors

Manufacturer
HORIBA
Model
3552-10D
Instrument type
Conductivity & resistivity sensors
Type
submersible conductivity cell with integrated temperature sensor
Cell constant
1 cm⁻¹
Measuring range
1 µS/cm to 100 mS/cm
Temperature range
0 to 100 °C
Sample volume required
15 ml
Electrodes
platinum, coated with platinum black
Body
glass
Connectors
BNC and phono jack
Cable length
1 m
Dimensions
length 150 mm, diameter 12 mm
Compliance
RoHS (EN IEC 63000)
Request a quote
Review enquiry

The 3552-10D is a submersible conductivity cell for general water quality measurement. It includes an integrated temperature sensor, which provides the sample temperature to the meter for temperature compensation of the conductivity reading.

The cell constant is 1 cm⁻¹, and the measuring range extends from 1 µS/cm to 100 mS/cm. The electrodes are made of platinum coated with platinum black and are mounted in a glass body. The cell can be used at sample temperatures from 0 to 100 °C.

With a diameter of 12 mm and a length of 150 mm, the cell is slim, and it requires a sample volume of only 15 ml. This allows measurements in small vessels and narrow containers in which larger cells cannot be immersed.

The cell is connected to the meter with a 1-metre cable carrying a BNC connector for the conductivity signal and a phono jack for the temperature sensor. It complies with RoHS requirements according to EN IEC 63000 and BS EN IEC 63000.

The 3552-10D is part of a series of conductivity cells that includes submersible types and flow types (other models in the series). As a submersible type, it is immersed directly in the sample, and its 1 cm⁻¹ cell constant makes it a general-purpose cell for the range from 1 µS/cm to 100 mS/cm.

The listed applications are general applications and water quality measurement.

When selecting a cell from the series, the expected conductivity, the available sample volume and the sample temperature are the main criteria; the 3552-10D suits general samples where only a small volume is available or where the temperature can reach 100 °C.

To request a quotation, please state the quantity and the meter to which the cell will be connected.

Part numbers · 1

3552-10D

Industry applications

Selection notes

Record the sample temperature, expected concentration and how the probe is mounted. Identify the mating transmitter when replacing a sensor.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU