Type 8203
Liquid analysis

pH & ORP electrodes
The 5002S-10C is a combination ion-selective electrode (ISE) for measuring the concentration of ammonium ions (NH4+) in liquid samples. It is intended for laboratory and field water quality analysis and is connected to a suitable meter via a BNC connector on a 1-metre cable.
The electrode works potentiometrically. It combines a glass electrode for pH measurement with a support pipe and a membrane cap that makes the assembly sensitive to ammonia. The internal electrode is Ag/AgCl, the internal filling solution is 0.1 mol/l NH4Cl and the liquid junction is of the movable sleeve type. The electrode slope is −54 to −62 mV per decade of concentration. Measurements are made at a sample pH of 12 or higher.
The measuring range extends from 0.01 to 18000 mg/l NH4+, corresponding to 5 × 10⁻⁷ to 1 mol/l, with an accuracy of ±2 %. The electrode can be used at sample temperatures from 0 to 50 °C.
The wetted parts are made of PTFE, PVC and PSU. The electrode is 161 mm long and 15 mm in diameter. It complies with RoHS (EN 50581, monitoring and control instruments), REACH and EMC requirements and with the Chinese standards GB/T 26572 and SJ/T 11364.
The electrode is supplied with accessories for operation and maintenance: three membrane caps, 50 ml each of 1000 mg/l and 100 mg/l ammonium ion standard solutions, 50 ml of ammonia electrode filling solution, a syringe, a dropper, a protective pipe and a manual. The standard solutions are used to calibrate the electrode, and the spare membrane caps and filling solution allow the sensing part to be renewed.
The listed fields of use are agriculture and soil analysis, power station water, fish tanks, sea water, waste water, plating baths, air and stack gases, and biological cultures or samples.
To receive a quotation, please state the quantity of electrodes, the meter you intend to use and whether additional membrane caps, standard solutions or filling solution are required.
5002S-10C, 500-NH3-IFS, 500-NH4-SL, 500-NH4-SH, 500-NH3-ISA, 300-NH4-C, Y052L, Y052H, 3551-10D, 3552-10D, 3553-10D, 3574-10C, 4163-10T, 501-S, 502-S, 503-S, 5401 DO Electrode Tip, 5402 DO Electrode Tip, 6069N-10C, 6252-10D, 6261-10C, 6367N-10D, 84 uS/cm Conductivity Standard Solution, 9300-10D, 9382-10D, 9415-10C, 9418-10C, 9425-10C, 9480-10C, 9481-10C, 9551-100D, 9618N-10D, 9625-10D, 9631-10D, 9632-10D, 9651-10D, 9680S-10D, 9681S-10D, AC adapter cable set, HC-200NH, LAQUA WQ-310-K, LAQUA WQ-320-K, LAQUA WQ-330-K, 0040N-10D, 6583S-10C, 7683S, S050, S051, 6560S-10C, 7660S, 110-10, 110-4, 110-7, 514-20, 6561S-10C, 9615S-10D
Record the sample temperature, expected concentration and how the probe is mounted. Identify the mating transmitter when replacing a sensor.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.