Fluke 53 II / 53IIB / 54IIB
Fluke

53 II / 53IIB / 54IIB digital thermocouple thermometer with data logging

Temperature calibrators

Manufacturer
Fluke
Model
53 II / 53IIB / 54IIB
Instrument type
Temperature calibrators
Thermocouple types
J, K, T, E, R, S, N
Inputs
1 (53 II / 53IIB) or 2 with T1−T2 differential (54IIB)
Accuracy J, K, T, E, N above −100 °C
±(0.05 % + 0.3 °C)
Accuracy R, S
±(0.05 % + 0.4 °C)
Accuracy below −100 °C
J, K, E, N ±(0.20 % + 0.3 °C); T ±(0.50 % + 0.3 °C)
Ranges
J −210…1200 °C; K −200…1372 °C; T −250…400 °C; E −150…1000 °C; N −200…1300 °C; R, S 0…1767 °C
Resolution
0.1 °C / 0.1 K below 1000; 1 °C / 1 K from 1000
Temperature scale / reference
ITS-90; NIST-175
Data logging
up to 500 points; intervals 1 s, 10 s, 1 min, 10 min or manual
Interface
IR USB communication port
Operating / storage temperature
−10 to 50 °C / −40 to 60 °C
Size, weight
173 × 86 × 38 mm, 400 g
Safety and EMC
EN/IEC 61010-1:2001, CAT I, pollution degree 2; EN/IEC 61326-1:2006
Approvals
CE, CSA, UL
Request a quote
Review enquiry

The 53 II series are handheld, microprocessor-based digital thermometers for contact temperature measurement with thermocouples, combined with data logging. They are offered as the single-input 53IIB and the dual-input 54IIB and are designed for laboratory accuracy as well as industrial use. The large backlit display is easy to read, and a sleep mode extends battery life to about 1000 hours.

The instruments accept industrial-standard J, K, T, E, N, R and S thermocouples. Temperature is referenced to ITS-90 and the thermocouple tables to NIST-175. The dual-input model measures T1 and T2 and also shows the difference T1−T2, which is useful for comparing two measuring points. An electronic offset function allows compensation of probe errors.

Accuracy is ±(0.05 % + 0.3 °C) for J, K, T, E and N thermocouples above −100 °C and ±(0.05 % + 0.4 °C) for R and S. Below −100 °C, accuracy is ±(0.20 % + 0.3 °C) for J, K, E and N and ±(0.50 % + 0.3 °C) for type T. Measuring ranges are −210 to 1200 °C (J), −200 to 1372 °C (K), −250 to 400 °C (T), −150 to 1000 °C (E), −200 to 1300 °C (N) and 0 to 1767 °C (R and S). Resolution is 0.1 °C below 1000 and 1 °C above.

Up to 500 readings are stored in internal memory, with recording intervals of 1 s, 10 s, 1 min, 10 min or manual. A recall function shows logged values on the instrument, and data is transferred to a PC through the IR USB communication port with compatible temperature PC software.

The thermometer measures 173 × 86 × 38 mm and weighs 400 g; it is splash- and dust-resistant and can be used in a holster with a flex stand. It operates from −10 to 50 °C and can be stored from −40 to 60 °C. The design meets EN/IEC 61010-1:2001 (CAT I, pollution degree 2, max. differential voltage 1 V) and EN/IEC 61326-1:2006, with CE, CSA and UL marks.

Accessories include thermocouple probes such as the 80PK-1 K-type bead probe and the 80PK-22, a holster and flex stand assembly, a ToolPak accessory and PC software. Listed uses are laboratory work, QA, process calibration and validation, calibration verification, food safety, HVAC, and checks on motors, insulation, breakers, pipes, corroded connections, liquids and wires. Annual calibration is recommended.

Please state the model (single or dual input), the thermocouple types and any probes or software needed with your enquiry.

Part numbers · 3

53 II, 53IIB, 54IIB

Industry applications

Selection notes

Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.