Fluke 5627A
Fluke

5627A secondary reference platinum resistance thermometer

RTD sensors

Manufacturer
Fluke
Model
5627A
Instrument type
RTD sensors
Sensor
platinum resistance thermometer, 100 Ω nominal, α = 0.00385 Ω/Ω/°C
Temperature range
−200 to 420 °C (6 in and 9 in versions to 300 °C)
Calibrated accuracy (k=2)
±0.026 °C at −196 °C; ±0.046 °C at 0 °C; ±0.077 °C at 200 °C; ±0.124 °C at 420 °C
Basic accuracy
±0.05 °C at 0 °C
Drift
±0.04 °C at 0 °C after 100 h at 420 °C
Response time
4 s max. (63.2 %, water at 3 ft/s)
Sheath
316 stainless steel, mineral insulated
Sizes
152 × 4.7 mm; 229 × 4.7 mm; 305 × 6.35 mm
Leads
4-wire, PTFE-insulated, nickel-plated copper, 22 AWG
Minimum immersion
100 mm
Bend option
minimum radius 19 mm
Request a quote
Review enquiry

The 5627A is a precision platinum resistance thermometer (PRT) intended as a secondary reference standard. It is used to calibrate industrial RTDs, thermocouples and temperature transmitters in baths, dry-well calibrators and furnaces, both in the laboratory and on site, and as the reference probe of digital thermometer readouts.

The sensing element is a 100 Ω platinum coil in a strain-relieving suspension, mounted in a mineral-insulated 316 stainless steel sheath. It follows the standard 385 curve (0.00385 Ω/Ω/°C), so it can be read by any DIN/IEC RTD meter, while individual calibration coefficients allow much higher accuracy with a precision readout. Four-wire PTFE-insulated leads cancel the resistance of the lead wires.

The working range is −200 °C to 420 °C for the 12-inch probe; the 6-inch and 9-inch versions are limited to 300 °C. Basic accuracy is ±0.05 °C at 0 °C. With the accredited calibration supplied with each probe, the expanded uncertainty (k=2) is ±0.026 °C at −196 °C, ±0.046 °C at 0 °C, ±0.077 °C at 200 °C and ±0.124 °C at 420 °C. Stability is documented: drift does not exceed ±0.04 °C at 0 °C after 100 hours at 420 °C. Response time is at most four seconds for a 63.2 % step in moving water.

Three lengths are available: 152 mm and 229 mm with a 4.7 mm diameter, and 305 mm with a 6.35 mm diameter. An immersion depth of at least 100 mm is recommended; the handle and the transition, rated from 0 °C to 150 °C, are not immersed. The sheath can be ordered bent at a minimum radius of 19 mm, except for the 50 mm closest to the tip, for applications with limited access.

The probe is offered with a choice of terminations to suit the readout: bare wires, spade or mini spade lugs, banana or mini banana plugs, gold pins, a 5-pin DIN connector, or memory connectors that store the calibration coefficients for automatic use by compatible thermometers and calibrators. Calibration is traceable to ITS-90 and performed under ISO 17025 accreditation.

Please state the required length, termination and readout model in your enquiry so that the probe is supplied ready for use.

Part numbers · 6

5627A-6-X, 5627A-9-X, 5627A-12-X, 5627A-6, 5627A-9, 5627A-12

Industry applications

Selection notes

Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.