Type 8203
Liquid analysis

Turbidity & suspended solids
The 6221 turbidity sensor, article TURB200, is a nephelometric sensor for measuring suspended particles in water samples. It is a flow-through unit with a 250 ml measuring cell and an integrated bubble trap, intended for low-range turbidity monitoring in drinking water and water treatment. The sensor works together with the EL200 controller, which is ordered separately.
Measurement follows the nephelometric method to ISO 7027 and EN 27027. A laser diode sends light through the sample, and a detector placed at 90 degrees to the beam picks up the light scattered by particles and converts it into a turbidity signal. The standard source is a visible red laser diode at 650 nm; an 860 nm infrared laser diode is available on request. Using these wavelengths avoids interference from sample colour. The stated lifetime of the light source is more than five years.
The standard measuring range is 0 to 100 NTU, with other ranges available on request. The detection limit is 0.015 NTU and repeatability is ±0.01 NTU. Accuracy is ±2 % or ±0.015 NTU, whichever is greater, up to 20 NTU, and ±5 % above 20 NTU. The integrated bubble trap removes air bubbles from the sample before it reaches the optical path.
Signal transmission is available as RS-232 or RS-485 with Modbus, or as a 4–20 mA output. The sensor is connected to the EL200 controller with a 3-metre cable.
The body is made of POM; wetted parts are POM, PP, FKM and quartz. Inlet and outlet fittings accept plastic tubing with an external diameter of 9.6 mm. The sensor is rated for 6 bar maximum at 25 °C and for ambient temperatures from −5 to 60 °C, and it is mounted on a wall with four screws. It complies with the RoHS Directive and the REACH Regulation and meets EMC requirements.
Listed applications are drinking water utilities, water reuse, water testing, aquaculture and municipal or industrial water treatment plants.
To request an offer, please state the measuring range, the light source (650 nm or 860 nm), the required output and whether the EL200 controller should be included.
TURB200
Record the sample temperature, expected concentration and how the probe is mounted. Identify the mating transmitter when replacing a sensor.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.