AHD 514 OP / AHD 514 OP B
Industrial automation & edge AI

Operator panels & HMI
The AGC 150 Remote Display is a remote access and control unit for the AGC 150 series of controllers. It acts as a mirror of the master controller: what the operator sees and can do on the master is available on the remote unit as well. This allows a controller to be accessed and operated over the local network from a secondary location, such as a central control room, or from a convenient place when the master itself is installed somewhere hard to reach, for example under a canopy or in stacked containers.
The remote unit connects to its master controller either through an Ethernet switch using TCP/IP or with a point-to-point cable. Over this link the operator can monitor and configure the controller parameters remotely. The data listed for the unit include CAN and Modbus TCP protocols and Ethernet, RS-485 and USB interfaces. The user interface is available in eight languages.
The technical data listed for the unit give a 12/24 V DC supply, a measuring voltage of 100–690 V AC at 50/60 Hz, measuring current of 1 A or 5 A with a burden below 0.3 VA, and a UL/cUL maximum of 600 V AC.
The enclosure is rated IP65. The unit measures 233.3 × 173.3 × 44.7 mm and weighs 0.79 kg. It is fitted into a panel cut-out of 218.5 × 158.5 mm (tolerance ±0.3 mm) and fixed with screw clamps; the panel may be up to 4.5 mm thick. The unit carries UL/cUL registration, and marine and offshore versions are listed.
The remote display is one of the building blocks of AGC 150 based systems. Listed fields of use include central control rooms, marine and offshore power management, hybrid and microgrid systems, and power generation sectors such as wind, hydro and battery energy storage, as well as data centres, hospitals, telecom, airports, infrastructure and fish farms.
When enquiring, please state the type of AGC 150 master controller in your system, the required connection method (Ethernet switch or point-to-point) and the number of remote units needed.
4189341185M
List the field signals, controller family and runtime environment. For edge processing, specify the workload, interfaces and available cabinet space.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.