The AHD 514 OP is the display and control unit of the AHD 514 monitoring system for marine diesel engines and generators. It shows operating and alarm data graphically and allows the engine to be started and stopped directly from the panel. The AHD 514 OP B variant is the remote station of the system and is typically installed on the bridge, so that the engine can be monitored and operated from the bridge control station as well as locally.
The unit communicates with the AHD 514 system over a CAN bus. It displays the system status and alarms and provides menu-guided functions through integrated control keys. Start and stop are operated with dedicated buttons; as a safety function against unintentional starts, the button has to be held for more than one second before the command is executed.
The 5.7-inch colour LCD has a resolution of 640 × 480 pixels with 15-bit colour depth and a viewable screen area of 116 × 87 mm. Its luminosity is 500 cd/m², and the backlight is dimmed automatically.
The unit is powered from 24 V DC (+30 % / −25 %) and draws at most 200 mA. It is a built-in device for desks and control cabinets, with a housing of 144 × 144 × 43 mm for a panel cutout of 131 × 131 mm, and weighs about 0.5 kg. The front is protected to IP56 and the rear to IP20. Operating temperature is −30 to +70 °C, and storage temperature −50 to +85 °C.
The unit carries type approvals of the classification societies ABS, BV and CRS and addresses the IACS E27 requirements. Several units can be cascaded: an additional AHD 514 OP can be connected, and the OP B version provides remote operation.
Typical installations are marine diesel engines, generators and bridge control stations. Please state whether you need the local unit (article 12974) or the remote bridge unit (article 14503) and how many control stations are planned when you request a quotation.
12974, 14503
List the field signals, controller family and runtime environment. For edge processing, specify the workload, interfaces and available cabinet space.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.