Surent G480
Flow

Ultrasonic flowmeters
The BCU series is a clamp-on ultrasonic flow meter purpose-built for single-use or hybrid bioprocessing applications. It delivers real-time liquid flow measurement without ever contacting the liquid, which preserves sterility and minimises validation effort.
The meter is clamped onto the outside of the process tubing and measures the liquid flow by the ultrasonic principle. Because the design is non-invasive, the tubing does not have to be cut to install the meter, which reduces the risk of contamination and the cleaning requirements. Each unit is factory calibrated using standard bioprocess tubing. As the meter is simply clamped on, it can be fitted to a tubing line without opening the flow path, and it can be removed again in the same way.
The flow range is 0 to 80,000 mL/min, corresponding to a maximum flow of 4800 L/h, and accuracy is ±1.0 % of rate. The meter operates at temperatures from 0 to 60 °C and is a measuring-only device (meter) without control function.
Connectivity is provided by a native EtherNet/IP interface, and the device is ODVA conformant, so it can be integrated directly into control systems that use EtherNet/IP. An integrated web-based server is used for configuration and diagnostics, and advanced diagnostic functions with alarms are included. The diagnostics and alarms are available both through the web server and over the EtherNet/IP connection, so the measured flow and the status of the meter can be monitored from the control system of the skid or platform.
The housing has a cleanroom-ready form factor and is rated IP66. The meter carries an EU Declaration of Conformity. Five models are listed: BCU0250, BCU0375, BCU0500, BCU0750 and BCU1375.
Applications named for the BCU series include upstream and downstream bioprocessing, chromatography skids, media preparation, final fill operations, single-use or hybrid OEM platforms, CDMO batch and continuous processes, tangential flow filtration and perfusion bioreactor systems.
When requesting an offer, please state the tubing type and size, the expected flow range, the model if known, and the number of meters required.
BCU0250, BCU0375, BCU0500, BCU0750, BCU1375
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.