Type 8189
Level

Hydrostatic level probes
The Beluga is a submersible area velocity flow meter designed for accurate flow monitoring in open channels. It provides bi-directional flow data with real-time alarming and is suitable for both temporary and permanent installations in wastewater and collection systems.
An area velocity meter determines flow from the flow velocity and the wetted cross-section, which is derived from the measured level. The Beluga uses a replaceable pressure level sensor and outputs flow directly, without an intermediate controller. Because the measurement is bi-directional, flow in both directions is recorded.
Stated accuracy is ±1 % zero stability. The meter operates at temperatures from −20 to 50 °C.
The cable is mounted on the side of the meter body, which prevents debris from becoming entangled with it in the channel. Data is sent directly to remote monitoring software, where it is available for real-time alarms and analysis. The meter is compatible with the RU-35 submersible RTU and data logger and with the corresponding remote monitoring software.
Applications listed for the Beluga cover open channel flow measurement and collection system monitoring, wastewater treatment, combined sewer overflow (CSO) and sanitary system overflow (SSO) monitoring, inflow and infiltration analysis, surcharge monitoring and custody transfer billing.
The main features of the meter are therefore its submersible design for open channel flow, bi-directional measurement, ±1 % zero stability, the replaceable pressure level sensor, the side-mounted cable for debris resistance, real-time alarming and compatibility with the RU-35 data logger.
Please state the channel or pipe shape and size, the expected flow and level range, the application (for example CSO, SSO or inflow and infiltration monitoring), whether the installation is temporary or permanent, and the data logger or telemetry to be used in your enquiry.
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.