Surent G480
Flow

Variable area flowmeters
The BGN is an all-metal variable area flow meter for reliable flow measurement of liquids, gases and steam under demanding process conditions. It is used in the chemical and petrochemical industry, oil and gas, food and beverage, pharmaceutical and process industries and power generation, for flow measurement, dosing, process monitoring and control, including hazardous areas.
The measuring principle is variable area. A float in a conical measuring section is lifted by the flow until equilibrium is reached, so its position corresponds to the instantaneous flow rate. The position is transferred by a magnet to a pointer on the scale or to an electronic transmitter, and the flow is indicated directly as volumetric or mass flow. A purely mechanical, non-electrical explosion-proof version is available.
Measuring ranges extend from 0.5…5 l/h up to 13,000…130,000 l/h of water and from 0.015 to 240 m³/h of air. Accuracy for the BGN-S and BGN-H is ±1.6 % for liquids and ±1.8 % for gases; for the BGN-P it is ±2 % for liquids. Repeatability is ±0.5 % of full scale. Standard pressure ratings are PN40 for DN15–80 and PN16 for DN100–150, with special versions up to PN400 and process pressures up to 600 bar. Medium temperatures are −40 to 200 °C for BGN-S/H and −20 to 125 °C for BGN-P, and special versions cover −80 to 350 °C.
The electronic transmitter ES provides 4–20 mA with HART, PROFIBUS PA or Foundation Fieldbus. Limit switches KEI1, KEI2, KER1 and KER2 provide one or two NAMUR contacts, and a pulse output is available. Protection is IP65 to IP67. The meter carries ATEX and IECEx approvals with marking II 2G Ex h IIC T6…T3 Gb and II 2D Ex h IIIC T85 °C…T350 °C Db, as well as PED, SIL to IEC 61508, KC, NEPSI and PESO approvals, and follows VDI/VDE 3513-2.
Wetted parts are 1.4404 (316L) or 1.4571 (316Ti) stainless steel as standard, with special materials such as Hastelloy C-22, Monel, 1.4439 and 1.4539, or a PTFE lining for corrosive media. Connections include flanges to EN 1092, ASME B16.5, DIN 2512 and JIS, G and NPT threads, tube fittings and dairy connections. Options are an integrated heating jacket, gas or liquid damping, a differential pressure regulator, a self-draining version and a displaced indicator unit. Pipes should be clean, and a magnetic filter is recommended for media with ferrous particles.
Please send the medium, flow range, pressure, temperature, nominal size and required outputs with your enquiry.
BGN-S50, BGN-P40, BGN - S, BGN - P, BGN - H
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.