Type 8203
Liquid analysis

Conductivity & resistivity sensors
CDCN442 is a toroidal conductivity analyser for industrial process monitoring of conductivity and concentration. It combines a controller with a toroidal, electrodeless sensor in a PVDF body.
A toroidal sensor contains two coils sealed in the sensor body. One coil induces a current in the liquid that flows through and around the sensor, and the second coil measures this current, which depends on the conductivity of the liquid. Because there are no electrodes in contact with the medium, the measurement does not rely on electrode surfaces. Automatic temperature compensation is applied, with a compensation range of 0 to 200 °C.
The conductivity measurement covers 10 mS/cm to 1 S/cm, and ranges from 5 to 2000 mS/cm are stated for the sensor. Cell constants of 0.01, 0.1, 1 or 5/10 cm⁻¹ are available, and the resolution is 0.1 or 0.01. The process temperature range is 0 to 130 °C, and the analyser operates at ambient temperatures from 5 to 40 °C.
The analyser provides two 4–20 mA outputs. One serves as a recorder output, and the control output can be programmed as P + I + D control. Two on/off alarm relays with normally open contacts are rated 1 A / 240 V AC. Galvanic isolation is 2000 V AC, and an RS485 digital interface allows integration into control systems. Readings are shown on a 2 × 16 digit LCD. Power consumption is 3.5 VA at 50/60 Hz.
The enclosure is rated IP68 and NEMA 4X and is made of ABS and cast aluminium SAE 323. The analyser can be mounted in a panel (DIN 144 × 144 × 100 mm), on a 2-inch tube or on a flat surface; installation hardware, stainless steel clamps, nuts and washers are included. The sensor has a 2-inch threaded process connection; CIP and other connections are available on request, as are other temperature compensation ranges. The analyser carries CE marking.
Listed applications are industrial process monitoring, conductivity measurement and concentration analysis. Please send the medium, expected conductivity range, process temperature and process connection with your enquiry.
CDCN442-Controller
Record the sample temperature, expected concentration and how the probe is mounted. Identify the mating transmitter when replacing a sensor.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.