Type 8203
Liquid analysis

Conductivity & resistivity sensors
The CDTX-111 and CDTX-112 are panel-mount instruments for in-process monitoring and control of conductivity, resistivity and temperature. They are microprocessor-controlled and combine measurement, display and control in one unit: two programmable relays and an isolated analogue output can drive dosing, alarms or valves directly from the measured value.
The instruments work with separately supplied conductivity cells of the CDE-100 series, available with cell constants from K = 0.01 to K = 30. Depending on the cell and the selected range, conductivity is measured from 0–999.9 µS/cm up to 0–600 mS/cm, with intermediate ranges of 0–9999 µS/cm and 0–100 mS/cm. For pure water the instrument can measure resistivity from 0 to 18 MΩ (or 0 to 19.99 µS/cm). Temperature is measured from 0 to 100 °C, and the reading is corrected by automatic or manual temperature compensation. Stated accuracy is ±1 %.
The isolated 4–20 mA output has selectable zero and span and an accuracy of ±0.02 mA. The two on/off relay outputs are rated 10 A and can be programmed as set points for control or alarm functions. The value is shown on an LCD with 13 mm digits; LED display options are also offered.
The CDTX-111 is built in 1/8 DIN format and the CDTX-112 in 1/4 DIN format. The front is rated IP54. Permitted operating conditions are −10 to 55 °C, 5 to 95 % RH and altitudes up to 3000 m, on 50/60 Hz supply. The instruments carry CE and RoHS markings.
The controllers are installed in a panel; the stated cut-out is 92 × 92 mm, with a height of 96 mm and a length of 110 mm. Sensors are not included and must be ordered separately: the CDE-100 cells are offered in versions such as CDE-100-001, -01, -1, -10 and -30, so that the cell constant can be matched to the range of the process.
Typical applications are water testing, pure water resistivity monitoring, high-conductivity process monitoring and dosing control loops. When you enquire, please state the conductivity or resistivity range of your medium, the preferred panel format and which conductivity cell you need.
CDTX-111, CDTX-112, CDE-100-001, CDE-100-01, CDE-100-1, CDE-100-10, CDE-100-30
Record the sample temperature, expected concentration and how the probe is mounted. Identify the mating transmitter when replacing a sensor.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.