Surent G480
Flow

Differential pressure flow elements
CFO-ONE is an automatic critical flow orifice unit for verifying the accuracy of constant volume sampler (CVS) systems used in exhaust gas testing. It performs the propane injection test that checks the accuracy and integrity of the CVS.
In the test, CFO-ONE injects a metered amount of propane through a critical flow orifice into the exhaust plenum. At critical flow the gas flow through the orifice depends on the upstream pressure and temperature, so the unit measures the gas temperature with a Pt100 sensor (0–100 °C) and the absolute gas pressure (0–100 psia), and controls the supply with an automatic pressure regulator operating from 0 to 950 kPa. The propane concentration calculated from the injected amount is then compared with the reading of the CVS to verify its accuracy.
The volume flow range is 0.0022 to 0.0282 SCFM with an accuracy of ±0.4 % of full scale. The unit holds two orifices chosen from five sizes: 0.002, 0.0025, 0.004, 0.005 and 0.0055 in. It is calibrated for any single CVS flow rate between 1.7 and 30 m³/min, for any single injection gas concentration between 1 and 800 ppm and for a gas supply pressure between 30 and 80 psig (45–95 psia). Orifice pressure and temperature indicators cover 0–100 psia and 0–100 °C. Calibration is carried out in an ISO 17025 compliant laboratory.
For automated testing, CFO-ONE is controlled over LAN via the AK host protocol or the integrated STARS VETS driver. It runs on 100–240 V AC, 50/60 Hz.
The system consists of the CFO unit, stainless steel braided hoses and a carry case. The unit is connected to the CVS with a quick-connect fitting and the braided hoses. It is portable, measures 298 × 340 × 150 mm and weighs 10 kg. Operating conditions are 0 to 40 °C, below 80 % relative humidity and altitudes from 0 to 1500 m. The unit complies with the EMC Directive 2014/30/EU, the Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU, and with BS EN 61326-1 and BS EN 61010-1.
Applications are automotive testing, verification of exhaust gas sampling systems and CVS calibration checks.
Please send the CVS flow rate, the injection gas concentration and the orifice sizes required with your enquiry.
CFO-ONE
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.