DwyerOmega Easidew
DwyerOmega

Easidew industrial dew point and moisture transmitters

Dew point & moisture analysers

Manufacturer
DwyerOmega
Model
Easidew
Instrument type
Dew point & moisture analysers
Measured values
dew point, moisture, temperature, pressure
Dew point ranges
−110 to 20 °C, −100 to 20 °C, −80 to 20 °C, −60 to 60 °C, −50 to 50 °C, −20 to 50 °C
Accuracy
±1 °C or ±2 °C (±2 K), depending on model
Outputs
4–20 mA or 0–1 V DC
Supply voltage
DC versions 3.3 V to 28 V DC; AC versions 85 to 265 V AC
Supply current
23 mA or 60 mA
Maximum operating pressure
10 MPa, 45 MPa or 52.5 MPa
Process connections
5/8 in UNF, 3/4 in UNF, 1/2 in BSP male
Sensor guard
10 µm HDPE standard; 80 µm stainless steel sintered
Housing
316 stainless steel, stainless steel or aluminium
Electrical connection
DIN 43650 C, M12 4- or 5-pin, screw terminal, dual 3/4 in NPT gland
Operating temperature
−40 or −20 °C to 60 or 85 °C
Protection
IP65, IP66, NEMA Type 4
Oxygen service
cleaned for oxygen service option; Kalrez O-ring for aromatics
Request a quote
Review enquiry

Easidew industrial dew point transmitters measure the moisture content or dew point of process gases, compressed air and liquids. They are used for continuous monitoring in a wide range of industrial settings, including hazardous environments, and the range includes explosion-proof and intrinsically safe versions as well as online hygrometers.

Depending on the model, the instruments measure dew point, moisture, temperature and pressure. The measured value is provided as a 4–20 mA current or a 0–1 V DC voltage output.

Dew point ranges include −110 to 20 °C, −100 to 20 °C, −80 to 20 °C, −60 to 60 °C, −50 to 50 °C and −20 to 50 °C. Accuracy is ±1 °C or ±2 °C, depending on the model. Maximum operating pressure is 10 MPa, 45 MPa or 52.5 MPa.

Supply voltage options cover DC versions from 3.3 V up to 28 V DC, including 24 V DC versions, and AC versions for 85 to 265 V AC; supply current is 23 mA or 60 mA. Electrical connection is made through DIN 43650 C or mini DIN 43650 C connectors, M12 4-pin or 5-pin connectors, screw terminals or a dual 3/4 in NPT gland, and cable lengths of 0.8 m, 2 m, 5 m and 10 m are available.

Process connections are 5/8 in or 3/4 in UNF male and 1/2 in BSP male. The sensor is protected by a 10 µm HDPE guard as standard or by an 80 µm sintered stainless steel guard. Housings are made of 316 stainless steel, stainless steel or aluminium and are rated IP65, IP66 or NEMA Type 4. Operating temperatures range from −40 °C or −20 °C up to 60 °C or 85 °C. Versions cleaned for oxygen service and a Kalrez O-ring for aromatic service can be specified.

The range includes the Easidew 2-wire dew point transmitter, the Easidew PRO XP explosion-proof moisture transmitter, the Easidew PRO IS and Easidew intrinsically safe transmitters, the Easidew Online and Easidew Advanced Online hygrometers, the SF82 2-wire transmitter and a digital low dew point and temperature probe.

Applications named for the range are trace moisture measurement in gases or liquids, compressed air and process gas monitoring, hazardous area dew point measurement, online hygrometer installations and moisture control in industrial processes. Please send the gas or liquid, the expected dew point range, the pressure, the area classification and the required output with your enquiry.

Industry applications

Selection notes

Identify the target gas, background gas and concentration units. State whether the sampling system is already installed or belongs in the enquiry.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU