Type 8189
Level

Conductive & optical level switches
The ELS-1100 series is a single-point electro-optic level sensor for economical liquid level detection without moving parts. It combines a compact polysulfone body with built-in switching electronics, so it connects directly to a controller input without a separate amplifier, and it can be used for high, low or intermediate level detection.
The sensor works on the electro-optic principle and detects the presence of liquid at its tip. Since there is no float or other moving part, there is nothing to stick or wear, and repeatability is ±1 mm.
The output is an open collector compatible with TTL and CMOS logic, which can sink up to 40 mA at up to 30 V DC. It is offered as dry sink, switching when the tip is dry, or wet sink, switching when the tip is in liquid. Supply versions are 10–28 V DC and 5 V DC. Electrical connection is made with 12 in long 22 AWG PVC leads.
The stem and mounting parts are made of polysulfone or nylon, and the wetted materials include nylon, polysulfone and fluorocarbon seals, which gives compatibility with a broad range of liquids. Mounting options are a 1/4 in NPT male thread, an M12 × 8g straight thread, a 1/2-20 UNF-2A thread and a fish pull ring for cable-suspended installation. The sensor can be installed through the top, bottom or side of the tank, in vertical or horizontal orientation. It withstands pressures up to 150 psi and operates from about −18 to 80 °C. The sensor weighs 227 g.
Typical uses are high, low or intermediate level detection and general-purpose liquid monitoring. Please indicate the mounting thread, output type, supply voltage and the liquid to be detected so that material compatibility can be checked.
146688, 169555, 148973, 144225, 171661, 216710, 148937, 213578, 175632, 143570, 143577, 148932, 175631, 175620, 143585, 175610, 175874, 144235, 143590, 258234, 219661, 258247, 249913, 238383, 250540
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.