Gems Sensors & Controls ELS-1100FLG
Gems Sensors & Controls

ELS-1100FLG flange-mount electro-optic level switch for thin-wall tanks

Conductive & optical level switches

Manufacturer
Gems Sensors & Controls
Model
ELS-1100FLG
Instrument type
Conductive & optical level switches
Type
single-point electro-optic level switch
Mounting
flanged, through 0.75 in (19 mm) hole, jam nut and Viton gasket
Tank wall thickness
up to 1/4 in (6 mm)
Orientation
horizontal or vertical
Housing material
polysulfone
Max. operating pressure
150 psi
Operating temperature
−18 to 80 °C (0 to 176 °F)
Supply voltage
5 V DC or 10–28 V DC
Electrical termination
leads
Configured versions
187575, 187580, 187585
Request a quote
Review enquiry

The ELS-1100FLG is a single-point electro-optic level switch designed for thin-wall tanks up to 1/4 in (6 mm) thick. Instead of a threaded process connection, it uses a flanged mounting design: the switch slips through a 0.75 in (19 mm) hole in the tank wall and is secured from the other side with a jam nut and sealed with a Viton gasket.

An electro-optic level switch detects the presence of liquid optically at a single point: the sensing tip responds when it is covered by liquid and when it is uncovered, so the switch signals whether the level is above or below its mounting position.

Because the switch needs no threads, there are no exposed threads inside the tank. This removes a potential breeding ground for bacteria and makes the design suitable for hygienic environments and medical applications. It also means that the tank wall does not have to be thick enough to cut a thread, which is why the switch suits sheet metal tanks and moulded plastic tanks.

The housing is made of polysulfone. The switch is rated for a maximum operating pressure of 150 psi and for operating temperatures from −18 to 80 °C (0 to 176 °F). It operates on 5 V DC or 10–28 V DC, and electrical termination is by leads. The switch can be mounted horizontally, through a side wall, or vertically, through the top or bottom of the tank.

Configured variants are listed under the part numbers 187575, 187580 and 187585.

Typical applications named for this switch are thin-wall tanks, sheet metal tanks, moulded plastic tanks and medical applications.

Installation is simple: drill a 0.75 in (19 mm) hole, insert the switch with its gasket, and tighten the jam nut.

Please send the required part number or the supply voltage, the mounting orientation and the tank wall material and thickness with your enquiry.

Part numbers · 3

187585, 187580, 187575

Industry applications

Selection notes

Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU