Gems Sensors & Controls ELS-1100HT
Gems Sensors & Controls

ELS-1100HT high-temperature electro-optic single-point level switch

Conductive & optical level switches

Manufacturer
Gems Sensors & Controls
Model
ELS-1100HT
Instrument type
Conductive & optical level switches
Sensing principle
electro-optic, single point
Supply voltage
5 V DC or 12 V DC
Current consumption
approx. 45 mA
Output
TTL/CMOS compatible transistor, wet or dry sink
Repeatability
±1 mm
Operating temperature
−40 to 230 °F (up to 100 °C)
Maximum pressure
150 psi
Wetted material
Isoplast
Mounting
3/8"-18 NPT male or M16 × 2
Leads
12–14" polymeric leads
Protection
NEMA 4X
Short version
HTS, 1/2" long
Request a quote
Review enquiry

The ELS-1100HT is a single-point electro-optic level switch for monitoring fluids at elevated temperatures. It is the high-temperature version of the standard ELS-1100 series and handles operating temperatures up to 230 °F (100 °C). The switch signals whether liquid is present or absent at its mounting point.

The sensor uses electro-optic sensing technology. The switching state changes with the presence or absence of liquid at the sensing tip, and the result is delivered through a TTL/CMOS compatible transistor output. The output can be configured as dry sink or wet sink, so that the switch signals either when the tip becomes dry or when it becomes wet. Repeatability is ±1 mm.

The unit operates from 5 V DC or 12 V DC supply, with a current consumption of approximately 45 mA. The permitted operating temperature range is −40 °F to 230 °F and the maximum pressure rating is 150 psi.

The body is made of high-performance Isoplast plastic, which offers broad chemical compatibility; Isoplast is also the only wetted material. Mounting threads are 3/8"-18 NPT male or M16 × 2, and electrical connection is made through 12–14" polymeric leads. A NEMA 4X rating is stated.

In addition to the standard length, a short HTS version that is 1/2" long is available. Ordering options therefore cover the supply voltage (5 V DC or 12 V DC), the output type (wet or dry sink), the mounting thread (3/8"-18 NPT or M16 × 2) and the standard or HTS length; article numbers such as 153061, 153062 or 181674 identify the individual configurations.

Applications given for the ELS-1100HT are coolant reservoir monitoring, medical diagnostic and sterilizer equipment, low lubricant warning on machine tools and low level warning in hydraulic reservoirs. For a quotation, please send the fluid and its temperature, the required supply voltage, wet or dry sink output, the mounting thread and the version length.

Part numbers · 8

153061, 153062, 153063, 153064, 181674, 181675, 191341, 191342

Industry applications

Selection notes

Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments