Type 8189
Level

Conductive & optical level switches
The ELS-1150XP is a single-point electro-optic level switch intended for OEM equipment where a liquid level must be detected at one defined point under high pressure and over a wide temperature range. The sensor body is very compact, only 1.38 inches (35 mm) long, and is screwed into the vessel or line through a 1/2" NPT male thread.
Detection is based on an electro-optic principle. The sensing tip is a fused glass prism: when the prism is in air, light emitted inside the sensor is reflected back to the receiver, and when the prism is covered by liquid the light is refracted out into the medium, so the change in received light indicates whether liquid is present. A microprocessor board evaluates the signal and drives the output. The fused glass prism is the element that allows the sensor to withstand high pressures.
The switch is rated for a maximum pressure of 5000 psi (2500 psi is also quoted as a typical figure in the product description) and for operating temperatures from −40 °F to 257 °F. It operates from a 5–28 VDC supply. The output is available as a 100 mA maximum sourcing output or as an open-collector output sinking 100 mA at 30 VDC maximum, and in dry or wet switching logic, giving four configurations: dry source, dry sink, wet source and wet sink. A programmable microprocessor version can be supplied with a custom time delay from 2 to 255 seconds.
Wetted parts are nickel-plated carbon steel and fused glass; the stem and mounting are stainless steel or nickel-plated carbon steel depending on the version. Electrical connection is by 72-inch, 18 AWG polyester leads. The sensor weighs about 0.5 lb (227 g) and can be mounted vertically or horizontally; the installation note recommends mounting horizontally or up to 45° from horizontal and avoiding air pockets and drips on the sensor tip. Nine configured variants are listed, including part numbers 227201 to 227204, 227254 to 227257 and 258236.
The series is aimed at OEM applications and, according to the manufacturer, is suited to corrosive environments. If the viscosity of different liquids is similar, the time delay of the optic sensor should be similar as well.
To request an offer, please send the required output configuration (source or sink, wet or dry), the medium, the operating pressure and temperature, and the quantity or part number.
227203, 227254, 227201, 227255, 258236, 227202, 227257, 227204, 227256
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.