Electromagnetic flowmeters
The EPX is an electromagnetic flow meter system for measuring the volume flow of electrically conductive liquids in closed piping systems, specifically in potentially explosive atmospheres. It consists of the EPX or PIT sensor and the UMF3 transmitter, available as a compact unit or as a remote version. ATEX and IECEx approvals cover Zone 1 for gas and Zone 21 for dust.
Measurement is based on Faraday's law of magnetic induction. Excitation coils create an alternating magnetic field across the insulated measuring tube; the conductive liquid flowing through it induces a voltage on the measuring electrodes that is proportional to the flow velocity. The UMF3 transmitter converts this signal into standard outputs. The meter causes no pressure drop and requires no maintenance. Bidirectional measurement is possible.
Sensors are available from DN 15 to DN 300, with pressure ratings of PN 40 or ASME Class 150/300 up to DN 50, PN 16 or Class 150 up to DN 200 and PN 10 or Class 150 for DN 250 and DN 300. The measuring range is 0.1 to 10 m/s. Accuracy is ±0.3 % of the measured value ±0.01 % of the flow at 10 m/s, and repeatability is ±0.15 % of the measured value ±0.005 %. Liquids must have a conductivity above 5 µS/cm, or above 20 µS/cm for demineralised water.
The UMF3 provides a passive, galvanically isolated 4–20 mA output with HART, a passive 1 kHz pulse output, a passive status output and a 24 V DC binary input, with standard or intrinsically safe outputs. It is supplied with 90–253 V AC, 50/60 Hz, or 24 V DC. Transmitter versions include non-Ex units and Ex d e ib, Ex d ib and Ex d ib [ia IIC Ga] IIB T4/T3 Gb units; a remote version with fixed sensor cable up to 10 m is available.
A wide choice of electrode and lining materials is offered, including hard rubber (−35 to +64 °C), soft rubber (+5 to +64 °C), E-CTFE and PTFE (up to +139 °C depending on temperature class). A grounding electrode can replace grounding rings. Flanges are steel or stainless steel 1.4301/SS316 to EN 1092 and ASME. Protection is IP67, with IP68 on request, and the device carries CE and PED conformity. Installation in hazardous areas must comply with EN 60079-14.
Applications are pressure-loss-free volume flow measurement of conductive liquids in industrial piping in explosive atmospheres; hydrogen is listed among the special fields.
Please send the nominal size, pressure rating, liquid, conductivity, temperature, lining, Ex zone and power supply with your enquiry.
UMF3, EPX, PIT, IS X.1XXEx
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.