Surent G480
Flow

Ultrasonic flowmeters
The FD-400 series is a Doppler ultrasonic flow meter for measuring the flow rate of liquids in pipes. It is intended for liquids that contain sonic reflectors such as suspended solids or gas bubbles, and is used in water treatment, wastewater, sewage, chemical processing and slurries. With clamp-on transducers, the measurement is non-intrusive: the pipe does not need to be opened.
The meter transmits ultrasound into the liquid, either through the pipe wall with clamp-on transducers or directly with an insertion probe. The sound is reflected by particles or bubbles moving with the liquid, and the frequency of the reflected signal is shifted in proportion to their velocity (Doppler effect). The monitor uses this frequency shift to calculate flow velocity and, with the pipe size, the flow rate.
The measuring range is 0.05 to 9 m/s (0.15 to 30 ft/s), and accuracy is ±2 % of full scale over the calibrated span. The meter can be used on pipes from 6 mm to 3 m (1/4 to 120 in). The response time is adjustable from 1 to 60 seconds.
The monitor is a wall-mount unit with an LCD and keypad that show flow rate and totalised volume. Outputs are available as 4–20 mA, dual control relays and rate pulse. Power supply options are 115/230 V AC ±15 %, 50/60 Hz at 5 VA or 12 to 28 V DC at 2.5 VA. The enclosure is rated IP66 / NEMA 4X for outdoor use, and the specified operating temperature range is −40 to 85 °C. The meter is RoHS compliant.
Transducers are sold separately from the monitor. Standard and high-temperature clamp-on transducers and insertion probe transducers are available, with cable lengths of 6 m as standard and 15 m or 30 m as options; armoured conduit can be supplied on request.
Please send the pipe material, diameter and wall thickness, the liquid and its solids or gas content, the flow range and temperature with your enquiry, so that the right transducer can be selected.
FD-400, FD-410, FD-411, FD-412, FD-413, FD-420, FD-422, FD-423, FD-430, FD-433, FD-400C-STD, FD-400C-SML, FD-400C-STD-HT, FD-400C-SML-HT, FD-400I-8, FD-400I-18, FD-400I-28, FD-400I-38, FD-400I-48, FD-400I-CR-18, FD-400I-CR-28, FD-400I-CR-38, FD-400I-CR-48, FD-400I-BV, FD-400I-SSV, FDT-GREASE, FD-GREASE, FDT-HT-GREASE, FDT-NS-GREASE
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.