DwyerOmega FGD10A
DwyerOmega

FGD10A flameproof Ex d fixed gas detector for oxygen, toxic and flammable gases

Gas detectors & alarms

Manufacturer
DwyerOmega
Model
FGD10A
Instrument type
Gas detectors & alarms
Detected gases
oxygen; toxic gases (e.g. CO, H₂S); flammable hydrocarbons
Sensors
plug-in replaceable: electrochemical, infrared, pellistor
Accuracy
±3 % FS (oxygen); ±5 % FS (toxic gases)
Resolution
0.1 % vol (O₂); 0.1 ppm (EC toxic below 50 ppm); 10 ppm to 1 % (CO₂, by range)
Response time
less than 15 s
Analogue output
4–20 mA, 10-bit
Relays
2 alarm levels and fault, 3 A at 300 V AC
Serial output
RS232, 19,200 baud
Supply
12 to 24 V DC, max. 5 W
Ambient conditions
from −20 °C; 0 to 95 %RH non-condensing; up to 1.1 bar
Protection
IP68 instrument body; IP65 sensor
Ex protection
Ex d IIC, ATEX and IECEx
Housing
die-cast aluminium or stainless steel 316; IR sensor housing SS 303
Dimensions
190 × 145 × 127 mm
Approvals
ATEX, IECEx, CE, UKCA
Request a quote
Review enquiry

FGD10A is a flameproof fixed gas detector for potentially explosive atmospheres in gas group IIC. It detects oxygen, toxic gases such as carbon monoxide and hydrogen sulphide, and flammable hydrocarbons, and passes alarms and measured values to the control system via relays, a 4–20 mA signal and an RS232 interface.

Gas concentration is measured by plug-in replaceable sensors of electrochemical, infrared or pellistor type, chosen to suit the gas to be detected; a sensor can be exchanged without replacing the detector. The detector has a 4-digit LCD and a keypad with four magnetically operated buttons; calibration and settings are made from outside with a magnetic pen, so the flameproof enclosure does not have to be opened in the hazardous area.

Stated accuracy is ±3 % of full scale for oxygen and ±5 % of full scale for toxic gases, and response time is less than 15 seconds. Resolution is 0.1 % volume for oxygen, 0.1 ppm for electrochemical toxic sensors below 50 ppm and 1 to 12 ppm for ranges of 50 to 1000 ppm; for CO₂ it ranges from 10 ppm to 1 % depending on the range.

Relay outputs provide two alarm levels and a fault signal, rated 3 A at 300 V AC. The analogue output is 4–20 mA with 10-bit resolution, and RS232 communication with a PC runs at 19,200 baud. The detector is supplied with 12 to 24 V DC and takes a maximum of 5 W. It operates from −20 °C at 0 to 95 %RH non-condensing and at pressures up to 1.1 bar.

The enclosure is available in pressure die-cast aluminium or stainless steel 316, with an infrared sensor housing in stainless steel 303. The instrument body is rated IP68 and the sensor IP65, and an optional weather guard is offered. Dimensions are 190 × 145 × 127 mm. The detector is certified Ex d IIC to ATEX and IECEx according to IEC 60079-0 and IEC 60079-1 and carries CE and UKCA marks; EMC conforms to EN 50270. A version without display, FGD10B, is also available.

Please tell us the gas to be detected, the measuring range, the enclosure material and the area classification, and we will configure the detector accordingly.

Part numbers · 1

FGD10A-Flameproof-Ex-d-Gas-Detector

Industry applications

Selection notes

Identify the target gas, background gas and concentration units. State whether the sampling system is already installed or belongs in the enquiry.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.