DwyerOmega FST200R
DwyerOmega

FST200R flow switch with compact relay controller

Flow switches & indicators

Manufacturer
DwyerOmega
Model
FST200R
Instrument type
Flow switches & indicators
Function
low-flow / no-flow detection
Media
liquids (FST-2xx-R) or gases (FST-3xx-R)
Pipe sizes
3/4 to 1½ in; 2 to 12 in
Flow velocity range
0.04 to 3 ft/s
Accuracy
±5 % of set point
Relay
SPDT, NO or NC selectable, up to 10 A or 1/2 hp
Time delay
0–60 s adjustable
Response time
10 s
Supply
120/240 V AC
Wetted materials
polypropylene or PVDF
Process connection
3/4 in NPT male
Max. pressure
150 psi
Process temperature
0 to 60 °C
Protection
IP66, NEMA 4X
Request a quote
Review enquiry

FST200R is a flow switch with an integrated compact relay controller for liquids and gases. It detects low flow or no flow in pipes and ducts and switches a relay that can directly operate a pump, valve, blower or alarm, so a complete flow monitoring function is built with one device and no separate controller.

The sensor detects the flow of the medium and compares it with the adjustable set point; accuracy is ±5 % of the set point and the measuring range covers flow velocities from 0.04 to 3 ft/s. When the flow falls below or rises above the set point, the SPDT relay changes state. The contact can be configured as normally open or normally closed and is rated up to 10 A or 1/2 hp, enough to switch small motors directly. An adjustable time delay from 0 to 60 seconds suppresses relay chatter caused by short flow fluctuations, and the response time is about 10 seconds.

LED indicators show the fluid status, relay status and power, which simplifies setting and troubleshooting. The device is supplied with 120 or 240 V AC. Electrical connection is made through a 1/2 in NPT conduit entry to a screw terminal block, and a 10 ft cable is used for the sensor.

The flow switch is entirely made of plastic, in polypropylene or PVDF. The 300° swivel base allows the housing to be aligned after installation. The sensor is installed with a 3/4 in NPT male connection directly in small pipes or with fittings in larger pipes up to 12 in. Maximum pressure is 150 psi, process temperature 0 to 60 °C and ambient temperature −40 to 60 °C. The housing is rated IP66 and NEMA 4X, and the device is CE marked.

Liquid versions (FST-2xx-R) and gas versions (FST-3xx-R) are available, each in polypropylene or PVDF, for pipe sizes from 3/4 to 1½ in or from 2 to 12 in, with matching fittings. Typical applications are low-flow protection of pumps, process monitoring and switching of valves, pumps or blowers. Please specify the medium, pipe size and material when requesting a quotation.

Part numbers · 10

FST-211-R, FST-212-R, FST-221-R, FST-222-R, FST-321-R, FST-322-R, FST-323-R, FST-324-R, FT-51, FT-52

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.