Surent G480
Flow

Turbine & positive displacement meters
The FT-210 Series is a compact low-flow turbine sensor for flow rate measurement and volume dispensing applications. It covers flows from 0.1 to 2.5 l/min (0.026 to 0.65 GPM, or 3.4 to 84.5 ounces per minute) and is used in water, coolant and chemical monitoring in OEM and industrial systems.
The sensor uses turbine technology. A lightweight turbine reacts quickly to the flow and generates a frequency output proportional to the flow rate, which gives fast start-up. The sensor is highly repeatable and is suitable for on/off dispensing. It can be mounted in any orientation.
The resolution is high: the sensor delivers 22,000 pulses per litre, equivalent to 83,200 pulses per gallon or 650 per ounce, and the frequency output ranges from 36.6 to 917 Hz across the flow range. Accuracy is ±3 % of reading, also at low flow. Permitted viscosity is 0.8 to 16 centistokes (32 to 70 SSU).
The output is an NPN sinking open collector rated at 20 mA maximum. The supply voltage is 5 to 24 V DC, and current consumption is 8 mA. The electrical termination is a 3-pin DIN connector with 9.4 mm spacing. A 1 m DIN PVC cable assembly with a 10 kΩ pull-up resistor and a mating DIN connector are available as options.
The body is made of Nylon 12, and wetted materials are Nylon 12 and PTFE with 15 % graphite. Ports are 1/4 in G or 1/4 in NPT male. The maximum operating pressure is 350 psi, the burst pressure 1400 psi (97 bar), and the operating temperature range −20 to 100 °C. Filtration of 50 microns is recommended. The sensor references NSF/ANSI/CAN 61 for drinking water system components.
Applications named are water, coolant and chemical monitoring, OEM systems, industrial systems and volume dispensing. Please state the port type, the liquid and whether the cable assembly is required in your enquiry.
212460, 212460E, 212465, 212465E, 212404, 250673, 256156, 257183, 264452, 250671-FS4, 263433, 217585, 245934, 261350, 19H256, 238461, 263432, 256388, 250671-FS2, 238460, 250671, 250671-FS1, 221901, 218572
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.