JBC
Motion and position feedback

Tachometers and speed pickups
The GE14 is a single-channel speed encoder of the tachogenerator type. It acquires shaft speeds under harsh operating conditions and delivers a sinusoidal alternating voltage as output signal. Its compact and robust design is suited to marine applications, and it is used in shipbuilding and on megayachts as well as in transport technology and defence.
The GE14 is mechanically connected to the shaft whose speed is to be measured. Depending on the installation, the connection is made by a flange, a bracket or a coupling; the version described here has a slotted coupling. When the shaft turns, the tachogenerator produces an AC voltage whose frequency is 0.1 times the speed. Because the signal is generated by the rotation itself, no external power supply is required.
The speed range is 150 to 3000 rpm. The operating temperature range is −20 to +80 °C. The housing is protected to IP65, and the drive side to IP54.
The GE14 is available in several standard types with different mechanical and electrical connections. Mechanical options include the slotted coupling, connection 8 and connection 2 according to DIN 5377, and a tilting shaft. Electrically, the device can be connected via a tab connector 6.3 × 0.8 according to DIN 46244 or via a TEGL cable 2 × 0.75. Listed versions are GE14-09, GE14-091, GE14-10 and GE14-12. In addition, tailored solutions are offered as -P types for installations with special requirements.
The tachogenerator carries the approvals of the classification societies DNV and LR.
Typical fields of use are marine applications, shipbuilding, megayachts, transport technology and defence. Please state the required mechanical connection, the electrical connection and the speed range of the shaft in your enquiry, and mention whether a type approval certificate is needed.
GE14-09, GE14-091, GE14-10, GE14-12
Compare the shaft or scale mounting, resolution and electrical interface with the receiving controller. For a replacement, record the connector, reference mark and direction of travel.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.