Surent G480
Flow

Variable area flowmeters
The GT1600 is a glass tube variable area flow meter for visual measurement of gas and liquid flows in industrial installations. It is intended both for new installations and for retrofit work: it can be configured to replace selected GT1000, GT1300 and Full-View 1100 series flow meters in existing panels and pipework.
The meter works on the variable area principle. A float inside a tapered glass tube rises with increasing flow until its weight is balanced by the force of the medium passing through the annular gap; the position of the float against the scale shows the flow rate. Because the indication is purely mechanical, no power supply is needed for local reading. The flow is read through a 180° viewing window.
For water the range extends up to 21 gpm (4,900 l/h), for air up to 150 scfm (270 m³n/h); the stated maximum flow is 2,438 slpm or 4,900 l/h. Several accuracy grades are offered: ±1 %, ±2 %, ±5 % and ±10 % of full scale, with class 2.5 to VDI/VDE listed as a standard option. Repeatability is ≤0.5 % of full scale. The meter operates at process temperatures from 1 °C to 121 °C. It is a measuring instrument only and does not control the flow by itself unless the optional needle valve is fitted.
The frame and fittings are made of 316 stainless steel, with 316/316L dual-certified material listed. The process connections are rotatable, which makes it easier to adapt the meter to the existing pipe routing, and maintenance can be carried out in situ. The meter is suitable for panel or wall mounting, and an outdoor version is listed. It is supplied with an EU Declaration of Conformity and complies with EU REACH.
Options include high and low flow alarms and an integral needle valve for setting the flow directly at the meter, as well as the choice of accuracy class.
Listed applications are purge and general industrial flow measurement, seal oil systems, bearing lubrication and cooling water indication, chemical and pharmaceutical processing, burner control, and water treatment and distribution systems.
To receive an offer, please send the medium, the required flow range, operating pressure and temperature, connection type, mounting method and whether alarms or a needle valve are required.
1610-JC-2-AA-0-0, 1610-JF-2-AA-0-0, 1610-LC-2-AA-0-0, 1610-LF-3-AA-0-0, 1610-MC-3-AA-0-0, 1610-MJ-3-AA-1-0, 1614-H3-1-AA-0-0, 1614-JF-2-AA-0-0, 1614-KC-2-AA-1-1, 1614-KF-2-AA-0-0, 1614-MF-4-AA-0-0, 1614-MJ-3-AA-0-0, 1620-UC-3-AA-2-0, 1624-SF-2-AA-0-0, 1630-PM-2-AA-1-0, 1634-PC-2-BA-0-0, 1640-A3-1-AA-1-0, 1644-D6-1-AA-0-0, 1644-G3-1-CA-0-0, 1644-H3-1-AA-0-0
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.