Valmet Flow Control Hawkeye HX
Valmet Flow Control

Hawkeye HX solid-state magnetic limit switch for valves

Proximity & presence sensors

Manufacturer
Valmet Flow Control
Model
Hawkeye HX
Instrument type
Proximity & presence sensors
Sensor type
solid-state magnetic sensor
Versions
HX35 universal voltage switching; HX45 NAMUR
NAMUR standard
EN 60947-5-6, intrinsically safe
Voltage (HX45)
5–29 V DC
Sensing range
8 mm (0.32″) max.
Enclosure
316 stainless steel
Potting
shock-absorbent urethane
Temperature range
−40 to +80 °C
Connection
1/2″ NPT, M20 or cable gland with 6 ft cord
Hazardous area
Ex i, Ex d; Class I, Division 1 and 2
Request a quote
Review enquiry

Hawkeye HX is a basic point sensing limit switch designed for harsh process environments. It indicates the position of a valve without mechanical contact and is suitable for linear valve applications such as gate and globe valves, as well as for knife gate, rotary and damper applications.

The switch uses a solid-state magnetic sensor. The valve position is detected via magnetic interaction, and the output switches when the sensed position is reached. The sensor module is encased and sealed in shock-absorbent urethane potting and housed in a stainless steel enclosure. This rugged construction with few parts is intended for harsh process environments.

Two output versions are available. HX35 offers universal voltage switching for direct connection to control circuits. HX45 is a NAMUR sensor according to EN 60947-5-6 for intrinsically safe circuits and operates on 5 to 29 V DC. The maximum sensing range is 8 mm (0.32 inch). The switches are rated for temperatures from −40 to +80 °C (−40 to +176 °F).

The enclosure is made of 316 stainless steel, which makes the switch corrosion-resistant. Electrical connection options are a 1/2-inch NPT entry, an M20 entry or a cable gland with a 6-foot cord. For hazardous locations the switch is available with intrinsic safety (Ex i) and explosion-proof/flameproof (Ex d) protection, and for Class I, Division 1 and Class I, Division 2 locations under the NEC.

Mounting hardware is required to install the switch on the valve and is sold separately, so the valve and actuator type should be known when ordering.

Listed industries are oil and gas, chemical processing, food and beverage, pharmaceutical and biotech, agri-processing, and mining and material handling. In these industries the switch provides position feedback from valves and dampers to the control system.

In summary, the HX range offers a stainless steel, corrosion-resistant enclosure, a solid-state magnetic sensor in a urethane-sealed module, explosion-proof/flameproof and intrinsically safe versions, a choice between universal switching and NAMUR outputs, and three types of electrical connection.

Please state the output type (HX35 or HX45), the connection, the hazardous area requirements and the valve and actuator type, so that the switch and mounting hardware can be specified together in our quotation.

Part numbers · 2

HX35, HX45

Industry applications

Selection notes

Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU